5. Commissioning
Installer level - Menu #PRIMARY INSTAL.PIMAIRE P.INSTAL}
Parameter
(3)
E. BL
BL
C004755-A
MIT.PUMP.DELAY
BACKUP TYPE
INDVIDUAL.RELIEVE
(7)
BACKUP PUMP DEL.
BACKUP ADD.DELAY
BACKUP BOOSTER DEL 0 to 10 min
DHW BACKUP
BOOSTER START DHW
(1) The menu is displayed only if the INSTALLATION parameter is set to EXTENDED
(2) The parameter is only displayed if the COOLING parameter is not set to OFF.
(3) The BL inlet must always be connected to a dry contact (potential-free)
(4) Active when the BL contact is opened.
(5) Active when the BL contact is closed.
(6) The parameter is only displayed if HYBRID ENABLED is set to COST
(7) The parameter is only displayed if BACKUP TYPE is set to /H
100
Adjustment range
Description
(4)
Total shutdown of the installation.
COMPLETE
Frost protection not guaranteed.
Shutdown - Frost protection of the
(4)
PARTIAL
installation
User reset
(5)
USER RESET
(5)
Power cut off of the back-ups on
BACK-UP MIT
the inside module
Power cut off of the back-ups on
(5)
AUCUN-APP+PAC
the inside module + Power cut off
of the DHW tank back-ups + HP
power cut off.
The installation is stopped. Frost
protection not guaranteed.
HP power cut off
(5)
COMPRESSOR
(5)
Power cut off of the back-ups on
BACK-UP MIT DHW
the inside module + Power cut off
of the DHW tank back-ups
(5)
Power cut off of the DHW tank
DHW BACKUP
back-ups
Power cut off of the DHW tank
WWE.KOMP ZUSATZ.
back-ups + HP power cut off
(5)
Power cut off of the back-ups on
COMP.MIT BACKUP
the inside module + HP power cut
(5)
off
(6)
Use of electricity tariff COST HIGH
PEAK/PEAK OFF
TARIFF in hybrid running
0 to 99 min
Post-operation time delay MIT
pump
Nature of back-ups
/E1
/E1: 1 stage electrical back-up
/E2
/E2: 2 stage electrical back-up
/H
/H: Hydraulic additional heating
OFF / ON
Power cut off generator 3
0 to 15 min
Post-operation time back-up
pump
0 to 50 min
Additional time delay on tripping
the back-ups
Time delay between stages or
time delay on tripping the back-
ups
Use of the electrical resistor in the
TANK
tank for DHW back-up
Use of the inside module back-ups
MIT
for DHW
Heating mode: Use of the inside
MIT/D.COOL
module back-ups for DHW
Cooling mode: Use of the
electrical resistor in the tank for
DHW back-up
0 to 50 min
DHW back-up trip time delay
(1)
Factory setting
1: PARTIAL
3 mn
OFF
4 mn
20 mn
4 mn
MIT
5 mn
AWHP-2 MIT-IN-2 iSystem
Customer
setting
25/06/2014 - 7616371-001-04