Connection Example For A System With Electrical Back-Up - DeDietrich AWHP-2 MIT-IN-2 iSystem Installation And Service Manual

Hide thumbs Also See for AWHP-2 MIT-IN-2 iSystem:
Table of Contents

Advertisement

AWHP-2 MIT-IN-2 iSystem
B
TS +
1
2
4
5 6
14
BUS
12
25/06/2014 - 7616371-001-04
SCU
0-10V
S AMB C
+ -
4 3 2 1 2 1
B
A
S SYST + TA -
S ECS
S EXT S DEP C
2 1
2 1
2 1
2 1
8
11
7
3
3
4.11.13.
Connection example for a system with
electrical back-up
PCU
S AMB B
S AMB A
2 1
2 1
S DEP B
2 1
2 1
4
10
13
A/B
A
B
Not used: Do not connect anything to the terminal block.
A
Z
CAUTION
Do not connect anything to the DHW pump
outlet as the reversal valve is connected to the
PCU PCB in the boiler.
Connect the outside temperature sensor.
E
Connect the 3-way valve motor (circuit B) and the circuit
R
B flow sensor.
Connect the heating pump (Circuit B).
T
Connect a safety thermostat if the heating circuit is for
Y
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Connect the DHW sensor.
U
4. Installation
9
M003034-B
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mit-in-2/eMit-in-2/h

Table of Contents