2BT

1-2-3 Installation environment

1. Temperature: 10 - 32.5°C/50 - 90.5°F
2. Humidity: 20 - 85%RH
3. Power supply: 120 V AC, 9 A
220 - 240 V AC, 4.8 A (average 2.5 A)
4. Power source frequency: 50 Hz ±0.3%/60 Hz ±0.3%
5. Installation location
• Avoid direct sunlight or bright lighting. Ensure that the photoconductor will not be exposed to direct sunlight or other
strong light when removing paper jams.
• Avoid extremes of temperature and humidity, abrupt ambient temperature changes, and hot or cold air directed onto
the machine.
• Avoid dust and vibration.
• Choose a surface capable of supporting the weight of the machine.
• Place the machine on a level surface (maximum allowance inclination: 1° ).
• Avoid air-borne substances that may adversely affect the machine or degrade the photoconductor, such as
mercury, acidic of alkaline vapors, inorganic gasses, NOx, SOx gases and chlorine-based organic solvents.
• Select a room with good ventilation.
6. Allow sufficient access for proper operation and maintenance of the machine.
Machine front: 1000 mm/39
Machine right: 300 mm/11
c
b
Figure 1-2-1 Installation dimensions
1-2-2
3
/
" Machine rear: 300 mm/11
8
13
/
" Machine left: 500 mm/19
16
f
a
13
/
"
16
11
/
"
16
d
e
13
a: 376 mm/14
/
"
16
9
b: 497 mm/19
/
"
16
3
c: 691 mm/27
/
"
16
9
d: 497 mm/19
/
"
16
5
e: 847 mm/33
/
"
16
1
f: 845 mm/33
/
"
4