2BT
Maintenance
item No.
U060
Adjusting the scanner input properties
Description
Adjusts the image scanning density.
Purpose
Used when the entire image appears too dark or light.
Method
Press the start key.
Setting
1. Change the setting using the zoom +/– keys.
Description
Image scanning density
Increasing the setting makes the density lower, and decreasing it makes the density higher.
2. Press the start key. The value is set.
Test copy mode
While this maintenance item is being performed, copying from an original can be made in test copy mode.
Completion
Press the stop/reset key at the screen for selecting an item. The indication for selecting a maintenance item No.
appears.
Caution
The following settings are also reset to the initial values by performing this maintenance item:
• Exposure density gradient set in maintenance mode (U093)
• Exposure set in the copy default item of the copier management mode
U061
Turning the exposure lamp on
Description
Turns the exposure lamp on.
Purpose
To check the exposure lamp.
Method
1. Press the start key. "on" appears.
2. Press the start key. The exposure lamp lights.
3. To turn the exposure lamp off, press the stop/reset key.
Completion
Press the stop/reset key. The indication for selecting a maintenance item No. appears.
U063
Adjusting the shading position
Description
Changes the shading position.
Purpose
Used when white lines continue to appear longitudinally on the image after the shading plate is cleaned. This is
due to flaws or stains inside the shading plate. To prevent this problem, the shading position should be
changed so that shading is possible without being affected by the flaws or stains.
Method
1. Press the start key.
2. Change the setting using the zoom +/– keys.
Description
Shading position
Increasing the setting moves the shading position toward the machine right, and decreasing it moves the
position toward the machine left.
3. Press the start key. The value is set.
Test copy mode
While this maintenance item is being performed, copying from an original can be made in test copy mode.
Completion
Press the stop/reset key at the screen for adjustment. The indication for selecting a maintenance item No.
appears.
1-4-10
Description
Setting range
0 to 23
Setting range
Initial setting
–15 to +15
0
Initial setting
12
Change in value per step
0.254 mm