2BT
Maintenance
item No.
U161
Setting the fixing control temperature
Description
Changes the fixing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fixing problem on thick paper.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the item to be set by lighting a copy exposure indicator using the copy exposure adjustment keys.
2. Change the setting using the zoom +/– keys.
Copy exposure
indicator
Exp. 1
Exp. 3
The temperatures are to be set such that exp. 3 ≥ exp. 1.
3. Press the start key. The value is set.
Completion
To exit this maintenance item without changing the current setting, press the stop/reset key. The indication for
selecting a maintenance item No. appears.
U162
Stabilizing fixing forcibly
Description
Stops the stabilization fixing drive forcibly, regardless of fixing temperature.
Purpose
To forcibly stabilize the machine before the fixing section reaches stabilization temperature.
Method
1. Press the start key. "on" appears.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regardless
of fixing temperature. The indication for selecting a maintenance item No. appears.
To exit the forced stabilization mode, turn the power off and on.
Completion
Press the stop/reset key. The indication for selecting a maintenance item No. appears.
U163
Resetting the fixing problem data
Description
Resets the detection of a service call code indicating a problem in the fixing section.
Purpose
To prevent accidents due to an abnormally high fixing temperature.
Method
1. Press the start key. "CLE" appears.
2. Press the start key. The fixing problem data is initialized.
Completion
Press the stop/reset key. The indication for selecting a maintenance item No. appears.
1-4-24
Description
Description
Primary stabilization fixing temperature
Secondary stabilization fixing temperature
Setting range
Initial setting
100 to 165 (°C)
125
155 to 195 (°C)
180