(3) Detaching and refitting the laser scanner unit

Take the following procedure when the laser scanner unit is to be checked or replaced.
Procedure
1. Open the front cover and remove the waste
toner tank and toner container.
2. Remove the printer cover and right cover.
3. Detach the two connector of the operation
unit.
4. Remove the two screws holding the eject tray
and then the tray.
5. Remove the three screws holding the laser
scanner unit.