(15) Image is partly miss-
ing.
Causes
1. Paper damp.
2. Paper creased.
3. Drum condensation.
4. Flawed drum.
(16) Fixing is poor.
Causes
1. Wrong paper.
2. Defective pressure springs.
3. Flawed press roller.
(17) Image is out of
focus.
Causes
1. Defective image scanning unit.
Causes
1. Paper damp.
2. Paper creased.
3. Drum condensation.
4. Flawed drum.
Check the paper storage conditions.
Replace the paper.
Clean the drum.
Replace the drum (see page 1-6-29).
Causes
1. Wrong paper.
2. Defective pressure springs.
3. Flawed press roller.
Check if the paper meets specifications.
Replace the pressure springs.
Replace the press roller (see page 1-6-38).
Causes
1. Defective image scanning unit.
Replace the image scanning unit (see page 1-6-20).
Check procedures/corrective measures
Check procedures/corrective measures
Check procedures/corrective measures
2BT