Kyocera Mita KM-1505 Service Manual page 58

Table of Contents

Advertisement

Maintenance
item No.
U252
Setting the destination
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Method
Press the start key.
Setting
1. Select the destination using the zoom +/– keys.
Display
JPn
Inc
EUP
ASA
2. Press the start key. The setting is set, and the machine automatically returns to the same status as when
the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/reset key. The indication for
selecting a maintenance item No. appears.
Description
Description
Metric (Japan) specifications
Inch (North America) specifications
Metric (Europe) specifications
Metric (Asia Pacific) specifications
2BT
1-4-27

Hide quick links: