Replace The Developer - Kyocera Mita KM-1505 Service Manual

Table of Contents

Advertisement

2BT

(5) Replace the developer

Follow the procedure below to replace the developer.
Prucedure
1. Remove the image formation unit (see page
1-6-27).
2. Remove the screw and washer. While lifting
the hooks upward, slide the developing
section cover until removed.
3. Replace the developer and refit all the
removed parts.
• When disposing of the developer, tilt the
image formation unit in the direction of A
shown in the diagram and rotate the
developing spiral gear.
• Never turn the magnet roller when the drum
is installed.
• When refitting the developing section cover,
make sure that the cover and the three
hooks of the housing engage securely.
4. Run the maintenance item U130 to set the
initial setting for the developer.
1-6-32
Developing section cover
Hook
Hook
Figure 1-6-53
A
Hook