2BT
Code
Contents
C710
Toner sensor problem
• The sensor output voltage is outside
the range of 0.5 to 4.5 V during toner
control.
• The toner sensor control voltage
cannot be set within the setting range
when maintenance item U130 is run.
A730
Broken external temperature
(C730)
thermistor wire
• The input voltage is above 4.5 V.
A731
Short-circuited external temperature
thermistor
(C731)
• The input voltage is below 0.5 V.
1-5-10
Causes
Check procedures/corrective measures
Defective toner
Replace the toner sensor.
sensor.
Poor contact of
Reinsert the connector. Also check for
the toner sensor
continuity within the connector cable. If
connector
none, repair or replace the cable.
terminals.
Developer
Replace the developer.
problem.
Poor contact of
Reinsert the connector. Also check for
the humidity
continuity within the connector cable. If
sensor PCB
none, repair or replace the cable.
connector
terminals.
Defective external
Replace the humidity sensor PCB.
temperature
thermistor.
Poor contact of
Reinsert the connector. Also check for
the humidity
continuity within the connector cable. If
sensor PCB
none, repair or replace the cable.
connector
terminals.
Defective external
Replace the humidity sensor PCB.
temperature
thermistor.
Remarks