Field Service Ver. 1.0 Jul. 2007
B. Reinstall procedure
[1]
[4]
[3]
[1]
[2]
3. Perform the following setting.
[Service Mode] → [ADF] → [Read Pos Adj]
See P.30 of the DF-611 service manual.
[2]
[4]
[3]
A00JF2C399DA
[3]
[1]
[2]
A00JF2C400DA
1. Mount the glass step sheet [1] to the
original glass moving unit [2].
NOTE
• Set the sheet [3] under the cover of
the original glass moving unit [4].
• Use care not to bend the edge of
the glass step sheet.
2. Set the points [1] of the glass step
sheet to the edge of the scale plate
on the original glass moving unit,
and mount it with three screws [2].
6. Other