Panasonic DP-C321 Service Handbook page 442

Digital color imaging system
Table of Contents

Advertisement

3-368
Button Names
Chain No. to be initialized at execution
Sys-System
- 700-
006,065?070,088.116,122,127,128,147,164?166,174
,176?181,197,208
- 701-912,917,924,929
- 720-002
- 730-001?006
- 770-124,203
- 780-065?068
- 785-008,009
- 790-003,004,099
- 801-104,204,304,404,504,604,704,804,904
- 802-004,104,204,304,404,504,604,704,804,904
- 803-004
- 810-002?019,038?127
- 820-003,007?009,017?019,024,026,027,029
- 823-001?005,008?011,030?047
- 830-001?004,084,085
- 850-001?004,007,009?012,015
- 860-009,013,020,025,031,032
Sys-User
Initialization Items for User
The items that can be changed by a User in the
following Chain No. will be initialized.
Chain No.: 700, 780, 785, 790, 800, 801, 802, 803,
804, 805, 806, 810, 820, 823, 830, 840
All
All of the above NVM will be initialized.
2. Select the button to be initialized and select [Execute].
3. The following message will appear. Select [Yes (Initialize)].
4. The message indicating the completion will appear.
5. Select the [Confirm] button.
This completes the initialization.
3. 6. 1. 2 Hard Disk Initialization (UI: DC305)
Only the hard disk in the partition A is initialized in the UI-Diag. Use PC-Diag DC355
when the other partitions are to be initialized.
Default size
Partition No.
(Gbytes)
Use
Partition 1 (A)
2
For copying
Partition 2 (B)
2
For printing
Partition 3 (C)
1.5
Scan, Mail Box, Secure Print
Partition 4 (D)
5
Spool Cont. control information, log
Partition 5 (E)
2
PDL, Others
Partition 6 (F)
0.5
Fonts, Form/Logo, SMB folder (config.txt, driver) Job
template
Initialization Procedure
1. Select [Hard Disk Initialization] on the Diagnostics screen in the CE mode.
The Partition A button will appear.
2. Select the Partition A button and select [Execute].
3. The following message will appear. Select [Yes (Initialize)].
4. The message indicating the completion will appear.
5. Select the [Confirm] button.
This completes the initialization of the Partition A.
3. 6. 1. 3 NVM Read/Write (UI:DC131)
All NVM can be set with the NVM Read/Write on the UI. However, be careful not to
input Chain-Link No. wrongly because the names of the NVM are not displayed on the
UI. (For the NVM items, refer to each Chain-Link No. in 3.5.6 Service Data.)
Procedure
1. Select [NVM Read/Write] on the Diagnostics screen in the CE mode.
2. Input the Chain-Link No. in six digits and press the [Confirm/Change] button.
3. The current setting value will be displayed. The text box for inputting the changed value
will be displayed.
E.g.) The machine does not accept "700-6" as a abbreviation of "700-006". Therefore,
input all 6 digits even though the first number is "0".
4. Input the number to be changed to. The number will be input in the changed value column.
5. Select [Confirm].
6. The input number will be displayed in the current number column.
This completes the NVM Read/Write operation.