Panasonic DP-C321 Service Handbook page 358

Digital color imaging system
Table of Contents

Advertisement

3-284
[Description]: Rising timing from Vm1 to VB1 at C Color Normal Speed.
25. 762-084
[NVM Name]: #K_DB DC VB1 On Normal Timing
[PSW Display]: #K_DB DC VB1 ON Normal Timing
[Initial Value]: 102
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Rising timing from Vm1 to VB1 at K Color Normal Speed.
26. 762-089
[NVM Name]: #Y_DB DC VB Off Normal Timing
[PSW Display]: #Y_DB DC VB OFF Normal Timing
[Initial Value]: 90
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Falling timing from VB to VB2 at Y Color Normal Speed.
27. 762-090
[NVM Name]: #M_DB DC VB Off Normal Timing
[PSW Display]: #M_DB DC VB OFF Normal Timing
[Initial Value]: 90
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Falling timing from VB to VB2 at M Color Normal Speed.
28. 762-091
[NVM Name]: #C_DB DC VB Off Normal Timing
[PSW Display]: #C_DB DC VB OFF Normal Timing
[Initial Value]: 90
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Falling timing from VB to VB2 at C Color Normal Speed.
29. 762-092
[NVM Name]: #K_DB DC VB Off Normal Timing
[PSW Display]: #K_DB DC VB OFF Normal Timing
[Initial Value]: 82
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Falling timing from VB to VB2 at K Color Normal Speed.
30. 762-093
[NVM Name]: #YM_DB AC On Normal Timing
[PSW Display]: #YM_DB AC ON Normal Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: AC Voltage Energized timing at YM Color Normal Speed.
31. 762-094
[NVM Name]: #CK_DB AC On Normal Timing
[PSW Display]: #CK_DB AC ON Normal Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: AC Voltage Energized timing at CK Color Normal Speed.
32. 762-095
[NVM Name]: #YM_DB AC On Normal Timing
[PSW Display]: #YM_DB AC OFF Normal Timing
[Initial Value]: 118
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: AC Voltage Off timing at YM Color Normal Speed.
33. 762-096
[NVM Name]: #CK_DB AC Off Normal Timing
[PSW Display]: #CK_DB AC OFF Normal Timing
[Initial Value]: 118
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: AC Voltage Off timing at CK Color Normal Speed.
34. 762-105
[NVM Name]: #Y_DB DC VB1 On Half-speed Timing
[PSW Display]: #Y_DB DC VB1 ON Half-speed Timing
[Initial Value]: 104
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Rising timing from Vm1 to VB1 at Y Color Half Speed.
35. 762-106
[NVM Name]: #M_DB DC VB1 On Half-speed Timing
[PSW Display]: #M_DB DC VB1 ON Half-speed Timing
[Initial Value]: 104
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Rising timing from Vm1 to VB1 at M Color Half Speed.
36. 762-107
[NVM Name]: #C_DB DC VB1 On Half-speed Timing
[PSW Display]: #C_DB DC VB1 ON Half-speed Timing
[Initial Value]: 104
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Rising timing from Vm1 to VB1 at C Color Half Speed.