37. 762-108
[NVM Name]: #K_DB DC VB1 On Half-speed Timing
[PSW Display]: #K_DB DC VB1 ON Half-speed Timing
[Initial Value]: 94
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Rising timing from Vm1 to VB1 at K Color Half Speed.
38. 762-113
[NVM Name]: #Y_DB DC VB Off Half-speed Timing
[PSW Display]: #Y_DB DC VB OFF Half-speed Timing
[Initial Value]: 92
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Falling timing from VB to VB2 at Y Color Half Speed.
39. 762-114
[NVM Name]: #M_DB DC VB Off Half-speed Timing
[PSW Display]: #M_DB DC VB OFF Half-speed Timing
[Initial Value]: 92
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Falling timing from VB to VB2 at M Color Half Speed.
40. 762-115
[NVM Name]: #C_DB DC VB Off Half-speed Timing
[PSW Display]: #C_DB DC VB OFF Half-speed Timing
[Initial Value]: 92
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Falling timing from VB to VB2 at C Color Half Speed.
41. 762-116
[NVM Name]: #K_DB DC VB Off Half-speed Timing
[PSW Display]: #K_DB DC VB OFF Half-speed Timing
[Initial Value]: 88
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Falling timing from VB to VB2 at K Color Half Speed.
42. 762-117
[NVM Name]: #YM_DB AC On Half-speed Timing
[PSW Display]: #YM_ DB AC ON Half-speed Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: AC Voltage Energized timing at YM Color Half Speed.
3-285
43. 762-118
[NVM Name]: #CK_DB AC On Half-speed Timing
[PSW Display]: #CK_ DB AC ON Half-speed Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: AC Voltage Energized timing at CK Color Half Speed.
44. 762-119
[NVM Name]: #YM_DB AC On Half-speed Timing
[PSW Display]: #YM_ DB AC OFF Half-speed Timing
[Initial Value]: 108
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: AC Voltage Off timing at YM Color Half Speed.
45. 762-120
[NVM Name]: #CK_DB AC Off Half-speed Timing
[PSW Display]: #CK_ DB AC OFF Half-speed Timing
[Initial Value]: 108
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: AC Voltage Off timing at CK Color Half Speed.
46. 762-121
[NVM Name]: #YMC_Deve Motor On Normal Timing
[PSW Display]: #YMC_Deve MOT ON Normal Timing
[Initial Value]: 184
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Color Developer during motor rising timing at Normal Speed.
47. 762-122
[NVM Name]: #YMC_Deve Motor Off Normal Timing
[PSW Display]: #YMC_Deve MOT OFF Normal Timing
[Initial Value]: 303
[Setup Range]: 0~1023 (1 Count: 2.4462 ms)
[Description]: Color Developer during motor falling timing at Normal Speed.
48. 762-123
[NVM Name]: #YMC_Deve Motor On Half-speed Timing
[PSW Display]: #YMC_Deve MOT ON Half-speed Timing
[Initial Value]: 184
[Setup Range]: 0~255 (1 Count: 4.8924 ms)
[Description]: Color Developer during motor rising timing at Half Speed.