Panasonic DP-C321 Service Handbook page 361

Digital color imaging system
Table of Contents

Advertisement

61. 762-180
[NVM Name]: #K_DB DC VB On Half-speed Timing
[PSW Display]: #K_DB DC VB ON Half-speed Timing
[Initial Value]: 370
[Setup Range]: 0~1023 (1 Count: 4.8924 ms)
[Description]: Rising timing from VB3 to VB at K Color Half Speed.
62. 762-185
[NVM Name]: #YMC_DB DC Normal VB3 Value
[PSW Display]: #YMC_DB DC Normal VB3 Value
[Initial Value]: 877
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: VB3 Developer DC Energized Voltage value of YMC Color/Normal
Speed.
63. 762-186
[NVM Name]: #K_DB DC Normal VB3 Value
[PSW Display]: #K_DB DC Normal VB3 Value
[Initial Value]: 877
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: VB3 Developer DC Energized Voltage value of K Color/Normal Speed.
64. 762-187
[NVM Name]: #YMC_DB DC Half-speed VB3 Value
[PSW Display]: #YMC_DB DC Half-speed VB3 Value
[Initial Value]: 877
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: VB3 Developer DC Energized Voltage value of YMC Color/Half Speed.
65. 762-188
[NVM Name]: #K_DB DC Half-speed VB3 Value
[PSW Display]: #K_DB DC Half-speed VB3 Value
[Initial Value]: 877
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: VB3 Developer DC Energized Voltage value of K Color/Half Speed.
66. 762-190
[NVM Name]: #K_DB DC Hi-speed VM1 Value
[PSW Display]: #4DB DC Hi-speed VM1 Value
[Initial Value]: 351
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: Vm1 Developer DC Energized Voltage value at K Color/High Speed.
3-287
67. 762-194
[NVM Name]: #K_DB DC Hi-speed VM3 Value
[PSW Display]: #K_DB DC Hi-speed VM3 Value
[Initial Value]: 877
[Setup Range]: 0~1023 (1 Count: -0.684 V)
[Description]: VB3 Developer DC Energized Voltage value at K Color/High Speed.
68. 762-195
[NVM Name]: #K_DB DC Vm0 On Hi-speed Timing
[PSW Display]: #K_DB DC Vm0 ON Hi-speed Timing
[Initial Value]: 107
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: Rising timing from 0v to Vm0 at K Color/High Speed.
69. 762-196
[NVM Name]: #K_DB DC Vm1 Off Hi-speed Timing
[PSW Display]: #K_DB DC Vm1 OFF Hi-speed Timing
[Initial Value]: 99
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: Falling timing from Vm1 to Vm0 at K Color/High Speed.
70. 762-197
[NVM Name]: #K_DB DC VB1 On Hi-speed Timing
[PSW Display]: #K_DB DC VB1 ON Hi-speed Timing
[Initial Value]: 130
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: Rising timing from Vm1 to VB1 at K Color/High Speed.
71. 762-202
[NVM Name]: #K_DB DC VB Off Hi-speed Timing
[PSW Display]: #K_DB DC VB OFF Hi-speed Timing
[Initial Value]: 91
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: Falling timing from VB to VB2 at K Color/High Speed.
72. 762-203
[NVM Name]: #CK_DB AC On Hi-speed Timing
[PSW Display]: #CK_DB AC ON Hi-speed Timing
[Initial Value]: 137
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: AC Voltage Energized timing at CK Color High Speed.
Chapter 3 Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-c401

Table of Contents