Panasonic DP-C321 Service Handbook page 305

Digital color imaging system
Table of Contents

Advertisement

[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
(303~803 ms)
46. 742-065
[NVM Name]: ADJUST PRE FEED POSITION TTM-1
[PSW Display]: ADJUST PRE FEED POSITION TTM-1
[Initial Value]: 0
[Setup Range]: 0~40 (1 Count: 10 ms)
[Description]: Adjust the Time between the FEED OUT SNR On and the FEED MOT
Off (0~400ms).
47. 742-066
[NVM Name]: ADJUST PRE FEED POSITION TTM-2
[PSW Display]: ADJUST PRE FEED POSITION TTM-2
[Initial Value]: 0
[Setup Range]: 0~40 (1 Count: 10 ms)
[Description]: Adjust the Time between the FEED OUT SNR On and the FEED MOT
Off (0~400ms).
48. 742-067
[NVM Name]: ADJUST PRE FEED POSITION TTM-3
[PSW Display]: ADJUST PRE FEED POSITION TTM-3
[Initial Value]: 37
[Setup Range]: 10~50 (1 Count: 10 ms)
[Description]: Adjust the Time between the FEED OUT SNR On and the FEED MOT
Off (100~500 ms).
49. 742-068
[NVM Name]: ADJUST PRE FEED POSITION 1TM-1
[PSW Display]: ADJUST PRE FEED POSITION 1TM-1
[Initial Value]: 0
[Setup Range]: 0~40 (1 Count: 10 ms)
[Description]: Adjust the Time between the FEED OUT SNR On and the FEED MOT
Off (0~400ms).
50. 742-072
[NVM Name]: MAIN FEED START TIMING TTM-1
[PSW Display]: MAIN FEED START TIMING TTM-1
[Initial Value]: 20
[Setup Range]: 0~44 (1 Count: 2.4462 ms)
[Description]: Adjust the Time between the MAIN FEED Starts and the PRE T/A
(330~830 ms).
3-231
51. 742-073
[NVM Name]: MAIN FEED START TIMING TTM-2
[PSW Display]: MAIN FEED START TIMING TTM-2
[Initial Value]: 20
[Setup Range]: 0~44 (1 Count: 2.4462 ms)
[Description]: Adjust the Time between the MAIN FEED Starts and the PRE T/A
(780~1280 ms).
52. 742-074
[NVM Name]: MAIN FEED START TIMING TTM-3
[PSW Display]: MAIN FEED START TIMING TTM-3
[Initial Value]: 20
[Setup Range]: 0~44 (1 Count: 2.4462 ms)
[Description]: Adjust the Time between the MAIN FEED Starts and the PRE T/A
(1410~1910 ms).
53. 742-075
[NVM Name]: MAIN FEED START TIMING 1TM-1
[PSW Display]: MAIN FEED START TIMING 1TM-1
[Initial Value]: 25 (580 ms)
[Setup Range]: 0~50 (1 Count: 10 ms)
[Description]: Adjust the Time between the MAIN FEED Starts and the PRE T/A
(330~830 ms).
54. 742-076
[NVM Name]: ADJUST SIDE REGI 2Tray
[PSW Display]: ADJUST SIDE REGI 2Tray
[Initial Value]: 18
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: SIDE REGI adjustment of 2TRAY
55. 742-077
[NVM Name]: ADJUST SIDE REGI 3Tray
[PSW Display]: ADJUST SIDE REGI 3Tray
[Initial Value]: 18
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: SIDE REGI adjustment of 3TRAY
56. 742-078
[NVM Name]: ADJUST SIDE REGI 4Tray
[PSW Display]: ADJUST SIDE REGI 4Tray
[Initial Value]: 19