3-218
75. 715-260
[NVM Name]: Speed Priority Background Color Suppression/For Color OFFSET
Value DADF Duplex Side Document Text
[PSW Display]: Color-Offset for Text DADF Duplex Side mode (Real Time AE)
[Initial Value]: 18
[Setup Range]: 0~255
[Description]: For AE OFFSET data DADF Duplex Side Document text in Color
model
76. 715-261
[NVM Name]: Speed Priority Background Color Suppression/For Color OFFSET
Value DADF Duplex Side Document Map
[PSW Display]: Color-Offset for Map DADF Duplex Side mode (Real Time AE)
[Initial Value]: 17
[Setup Range]: 0~255
[Description]: For AE OFFSET data DADF Duplex Side Document map in Color
model
77. 715-300
[NVM Name]: IIT Failure Bypass
[PSW Display]: IIT Failure Bypass
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: 0: Failure Bypass is not available, 1: Failure Bypass is available
78. 715-301
[NVM Name]: Slow Scan Direction Regi Correction Value
[PSW Display]: SS Registration Adjustment
[Initial Value]: 100
[Setup Range]: 16~184
[Description]: Slow Scan Direction Regi Correction Value (0.036mm/step)
"Adjustment at ex-factory"
79. 715-302
[NVM Display]: Slow Scan direction Magnification Correction Value
[PSW Display]: SS Magnification Adjustment
[Initial Value]: 50
[Setup Range]: 44~56
[Description]: Slow Scan direction Magnification Correction Value (0.1%/step)
"Adjustment at ex-factory"
80. 715-400
[NVM Name]: Switching of Platen model and ADF model
[PSW Display]: Platen/ADF
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: 0: Platen model 1: ADF model "Adjustment at ex-factory"
81. 715-401
[NVM Name]: Time between Power On/Energy Saver recovery and AGOC
[PSW Display]: AGOC Timing
[Initial Value]: 15
[Setup Range]: 0~29
[Description]: Time between Power On/Energy Saver recovery and AGOC (min)
(0: Timer not available
82. 715-800
[NVM Name]: IISS~ADF Communication Failure
[PSW Display]: lIISS/ADF Communication Failure Count Overall Total
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
83. 715-801
[NVM Name]: IISS~ADF Communication Failure
[PSW Display]: IISS/ADF Communication Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)
84. 715-802
[NVM Name]: IISS RAM CHECK Failure
[PSW Display]: lIISS RAM CHECK Failure Count Overall Total
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter (Write not permitted)
85. 715-803
[NVM Name]: IISS RAM CHECK Failure
[PSW Display]: IISS RAM CHECK Failure Count Since Reset
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative Failure Counter at the previous clearing
(Write not permitted)