102-326 Memory Overflow
[Detection Conditions]
Memory overflow
The memory in the GUAM exceeded the upper limit.
[Actions]
Expand the memory in the GUAM.
Perform re-installation of the software.
102-327 Button Overflow
[Detection Conditions]
Button overflow
The memory for the (synchronous display) button in
the GUAM exceeded the upper limit.
[Actions]
Expand the memory for the button in the GUAM.
Perform re-installation of the software.
102-328 UI Internal Failure with Out of Area
[Detection Conditions]
I/F failure in the UI
The coordination value out of the area of the displayed
screen was detected. (W x H = 640 x 240)
[Actions]
Check the D-RAM and ROM.
Perform re-installation of the software.
102-329 UI Internal Failure with Invalid Coordinates
[Detection Conditions]
I/F failure in the UI
The coordination value that cannot be displayed was
detected. (X = 4 times number position)
[Actions]
Check the D-RAM and ROM.
Perform re-installation of the software.
3-101
102-330 Interface Failure with Invalid Parameter
LCD
[Detection Conditions]
Interface failure
Incorrect parameter was detected at the Drv. I/F
between the DM and LCD.
[Actions]
Check the D-RAM and ROM.
Perform re-installation of the software.
102-331 UI Internal Failure with Invalid LED
Request
[Detection Conditions]
I/F failure in the UI
The request for lighting up an incorrect LED was
received.
[Actions]
Check the D-RAM and ROM.
Perform re-installation of the software.
102-332 Interface Failure with Invalid Parameter CP
[Detection Conditions]
Interface failure
Incorrect parameter was detected at the Drv. I/F
between the DM and CP.
[Actions]
Check the D-RAM and ROM.
Perform re-installation of the software.
102-333 Interface Failure with Impossible
Communication
[Detection Conditions]
Interface failure
Impossible communication with the Control Panel
was detected.
H/W connection failure in the Panel, or the internal
connection was unable to be detected correctly.
[Actions]
Perform re-installation of the software.
102-334 Interface Failure with Receiving Error Key
Code
[Detection Conditions]
Interface failure
Invalid Key Code was received from the Control Panel.
[Actions]
Repair/adjust the Control Panel. (PL16.2)
Panel-SW bug
102-335 Interface Failure with Receiving Invalid
Coordinates
[Detection Conditions]
Interface failure
Invalid coordination value was received from the
Control Panel with a parameter.
[Actions]
Repair/adjust the Control Panel. (PL16.2)
Panel-SW bug
102-336 Interface Failure DM - ACD Drv. I/F
[Detection Conditions]
Interface failure
Incorrect parameter was detected at the Drv. I/F
between the DM and ACD.
[Actions]
Check the D-RAM and ROM. Replace the Control
Panel. (PL16.2)