Panasonic DP-C321 Service Handbook page 324

Digital color imaging system
Table of Contents

Advertisement

3-250
[Initial Value]: 3
[Setup Range]: 0~3
[Description]:
Selection SW for Trigger types to operate the BCR CLN
0: CV COUNT
1: DRUM CYCLE COUNT
2: PIXEL COUNT
3: PV Count+ Pixel Count+DRUM Cycle
11. 751-160
[NVM Name]: CV COUNT TOTAL
[PSW Display]: CV COUNT TOTAL (Counter)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Each Cumulative ERU by Billing Count (1 Count=1pv)
12. 751-161
[NVM Name]: DRUM CYCLE COUNT TOTAL
[PSW Display]: DRUM CYCLE COUNT TOTAL (Counter)
[Initial Value]: 0
[Setup Range]: 0~65535
[Description]: Cumulative DRUM Cycle (1 Count=10cycle)
13. 751-162
[NVM Name]: PIXEL COUNT TOTAL
[PSW Display]: PIXEL COUNT TOTAL (Counter)
[Initial Value]: 0
[Setup Range]: 0~10000000
[Description]:
Cumulative K Color Pixcel Count
Units of 1 step is based on the ICDC Control Pixcel Count (1 Count=1dot/1 grada-
tion)
14. 751-167
[NVM Name]: No. of BCR CLN Operations
[PSW Display]: BCR Cleaning Count
[Initial Value]: 0
[Setup Range]: 0~1000
[Description]: Reads the No. of BCR CLN Operations. (1 Count=1 time)
15. 751-177
[NVM Name]: CRUWarning Threshold
[PSW Display]: P/R Life Warning (Limiter)
[Initial Value]: 265
[Setup Range]: 0~500
[Description]: Warning value of Drum Cartridge (All engine common)
(1 Count=1kCy)
16. 751-178
[NVM Name]: CRU End of Life Threshold
[PSW Display]: P/R Life End of Life (Limiter)
[Initial Value]: 280
[Setup Range]: 0~500
[Description]: End of Life value of Drum Cartridge (All engine common)
(1 Count=1kCy)
17. 751-191
[NVM Name]: BCR Cleaning Start Timing
[PSW Display]: BCR Cleaning Timing
[Initial Value]: 200
[Setup Range]: 0~700
[Description]:
Time between EVENT_CYCLE_UP and BCR Cleaning Start. (1 Count=10ms)
18. 751-200
[NVM Name]: VH Value after #Y_BCR DC Correction
[PSW Display]: #Y_BCR DC corrected VH value 104 mm/s
[Initial Value]: 620
[Setup Range]: 0~1023
[Description]: VH Output Value of #Y Engine after Correction (All Speed common)
(1 Count=-1.173V)
19. 751-201
[NVM Name]: VH Value after #M_BCR DC Correction
[PSW Display]: #M_BCR DC corrected VH value 104 mm/s
[Initial Value]: 620
[Setup Range]: 0~1023
[Description]: VH Output Value of #M Engine after Correction (All Speed common)
(1 Count=-1.173V)
20. 751-202
[NVM Name]: VH Value after #C_BCR DC Correction
[PSW Display]: #C_BCR DC corrected VH value 104 mm/s
[Initial Value]: 620
Chapter 3 Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-c401

Table of Contents