Panasonic DP-C321 Service Handbook page 362

Digital color imaging system
Table of Contents

Advertisement

3-288
73. 762-204
[NVM Name]: #CK_DB AC Off Hi-speed Timing
[PSW Display]: #CK_DB AC OFF Hi-speed Timing
[Initial Value]: 137
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: AC Voltage Off timing at CK Color High Speed.
74. 762-210
[NVM Name]: #K_DB DC VB On Hi-speed Timing
[PSW Display]: #K_DB DC VB ON Hi-speed Timing
[Initial Value]: 370
[Setup Range]: 0~1023 (1 Count: 1.3114 ms)
[Description]: Rising timing from VB3 to VB at K Color/High Speed.
75. 762-211
[NVM Name]: #1,2DB AC Target Value at 1200 dpi
[PSW Display]: #1, 2DB AC Target Value at 1200 dpi
[Initial Value]: 600
[Setup Range]: 0~1023 (1 Count: 1.491 V)
[Description]: AC peak to peak energized voltage at YM Color 1200dpi/Normal Speed
Setup
76. 762-213
[NVM Name]: #3,4DB AC Target Value at 1200 dpi
[PSW Display]: #3, 4DB AC Target Value at 1200 dpi
[Initial Value]: 600
[Setup Range]: 0~1023 (1 Count: 1.491 V)
[Description]: AC peak to peak energized voltage at CK Color 1200dpi/Normal Speed
Setup
77. 762-215
[NVM Name]: #1,2DB AC Target Value at 1200 dpi/Half Speed
[PSW Display]: #1, 2DB AC Target Value at 1200 dpi/Half-speed
[Initial Value]: 600
[Setup Range]: 0~1023 (1 Count: 1.491 V)
[Description]: AC peak to peak energized voltage at YM Color 1200dpi/Half Speed
Setup
78. 762-217
[NVM Name]: #3,4DB AC Target Value at 1200 dpi/Half Speed
[PSW Display]: #3, 4DB AC Target Value at 1200 dpi/Half-speed
[Initial Value]: 600
[Setup Range]: 0~1023 (1 Count: 1.491 V)
[Description]: AC peak to peak energized voltage at CK Color 1200 dpi/Half Speed
Setup
79. 762-219
[NVM Name]: toner_band_width_YMC
[PSW Display]: toner_band_width_YMC
[Initial Value]: 10
[Setup Range]: 0~30
[Description]: Xero/Deve band width Setup value at YMC Color
80. 762-220
[NVM Name]: toner_band_width_K
[PSW Display]: toner_band_width_K
[Initial Value]: 10
[Setup Range]: 0~30
[Description]: Xero/Deve band width Setup value at K Color
81. 762-221
[NVM Name]: toner_band_density_Half-speed_YMC
[PSW Display]: toner_band_density_Half-speed_YMC
[Initial Value]: 153
[Setup Range]: 0~255 (1 Count: 0.3922 %)
[Description]: Half Speed Xero/Deve band density setup value at YMC Color
82. 762-222
[NVM Name]: toner_band_density_Half-speed_K
[PSW Display]: toner_band_density_Half-speed_K
[Initial Value]: 153
[Setup Range]: 0~255 (1 Count: 0.3922 %)
[Description]: Half Speed Xero/Deve band density setup value at K Color
83. 762-223
[NVM Name]: toner_band_density_Normal_YMC
[PSW Display]: toner_band_density_Normal_YMC
[Initial Value]: 153
[Setup Range]: 0~255 (1 Count: 0.3922 %)
[Description]: Normal Speed Xero/Deve band density setup value at YMC Color
84. 762-224
[NVM Name]: toner_band_density_Normal_K
[PSW Display]: toner_band_density_Normal_K
[Initial Value]: 153
Chapter 3 Troubleshooting