109.762-252
[NVM Name]: #M_DB DC VB Off Hi-speed Timing
[PSW Display]: #M_DB DC VB OFF Hi-speed Timing
[Initial Value]: 366
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: Falling timing from VB to VB2 at M Color High Speed.
110.762-253
[NVM Name]: #C_DB DC VB Off Hi-speed Timing
[PSW Display]: #C_DB DC VB OFF Hi-speed Timing
[Initial Value]: 366
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: Falling timing from VB to VB2 at C Color High Speed.
111.762-254
[NVM Name]: #YM_DB AC On Hi-speed Timing
[PSW Display]: #YM_DB AC ON Hi-speed Timing
[Initial Value]: 366
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: AC Voltage Energized timing at YM Color High Speed.
112.762-255
[NVM Name]: #YM_DB AC Off Hi-speed Timing
[PSW Display]: #YM_DB AC OFF Hi-speed Timing
[Initial Value]: 366
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: AC Voltage Off timing at YM Color High Speed.
113.762-256
[NVM Name]: #Y_DB DC VB On Hi-speed Timing
[PSW Display]: #Y_DB DC VB ON Hi-speed Timing
[Initial Value]: 1382
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: Rising timing from VB3 to VB at Y Color High Speed.
114.762-257
[NVM Name]: #M_DB DC VB On Hi-speed Timing
[PSW Display]: #M_DB DC VB ON Hi-speed Timing
[Initial Value]: 1382
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: Rising timing from VB3 to VB at M Color High Speed.
3-291
115.762-258
[NVM Name]: #C_DB DC VB On Hi-speed Timing
[PSW Display]: #C_DB DC VB ON Hi-speed Timing
[Initial Value]: 1382
[Setup Range]: 0~2000 (1 Count: 1.3114 ms)
[Description]: Rising timing from VB3 to VB at C Color High Speed.
116.762-259
[NVM Name]: FPOT DB Vm0 On Normal Timing
[PSW Display]: FPOT DB Vm0 ON Normal Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: Rising timing from 0v to Vm0 at K Color FPOT.
117.762-260
[NVM Name]: FPOT DB Vm0 On Hi-speed Timing
[PSW Display]: FPOT DB Vm0 ON Hi-speed Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: Rising timing from 0v to Vm0 at K Color FPOT.
118.762-261
[NVM Name]: FPOT DB AC On Normal Timing
[PSW Display]: FPOT DB AC ON Normal Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 2.4462 ms)
[Description]: AC Voltage Energized timing at FPOT Normal Speed.
119.762-262
[NVM Name]: FPOT DB AC On Hi-speed Timing
[PSW Display]: FPOT DB AC ON Hi-speed Timing
[Initial Value]: 110
[Setup Range]: 0~255 (1 Count: 1.3114 ms)
[Description]: AC Voltage Energized timing at FPOT High Speed.