Panasonic DP-C321 Service Handbook page 319

Digital color imaging system
Table of Contents

Advertisement

62. 746-411
[NVM Name]: Output Remote for DTS 52 Side2
[PSW Display]: Output Remote for DTS half-speed Side2
[Initial Value]: 100
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 50: DTS voltage=-3000x0.5=-1500 V
63. 746-412
[NVM Name]: Output Remote for DTS 194 Side1
[PSW Display]: Output Remote for DTS twice-speed Side1
[Initial Value]: 0
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 0: DTS voltage=-3000x0=-0 V
64. 746-413
[NVM Name]: Output Remote for DTS 194 Side2
[PSW Display]: Output Remote for DTS twice-speed Side2
[Initial Value]: 50
[Setup Range]: 0~100 (1 Count: 1 %)
[Description]:
Displays the multiplication value by DTS output adjustment
ex
At 100: DTS voltage=-3000x1.0=-3000 V
At 50: DTS voltage=-3000x0.5=-1500 V
65. 746-423
[NVM Name]: Toner Band Width (In process direction)
[PSW Display]: Toner Band Width (in process direction)
[Initial Value]: 3
[Setup Range]: 0~22 (1 Count: 1 mm)
[Description]: For adjustment of Toner Band Width in process direction
3-245
66. 746-424
[NVM Name]: Toner Band Width (In axial direction)
[PSW Display]: Toner Band Width (in axial direction)
[Initial Value]: 137
[Setup Range]: 0~137 (1 Count: 1 mm)
[Description]: For adjustment of Toner Band Width in axial direction
67. 746-425
[NVM Name]: Toner Band Density
[PSW Display]: Toner Band Density
[Initial Value]: 60
[Setup Range]: 10~100 (1 Count: 1 %)
[Description]:
For adjustment of Toner Band Density
ex
60=cin60 %
50=cin50 %
68. 746-959
[NVM Name]: 2nd CLN MINUS BIAS OUTPUT (For Environment no.0, 1, 2, 3)
[PSW Display]: 2nd CLN MINUS BIAS OUTPUT (for Environment no.0, 1, 2, 3)
[Initial Value]: 123
[Setup Range]: 102~921 (1 Count: -4.888 V)
[Description]:
For 2ND BTR Cleaning Bias setup for each environment
The resistance detection result of remote cannot be reflected
69. 746-960
[NVM Name]: 2nd CLN MINUS BIAS OUTPUT (For Environment no.4)
[PSW Display]: 2nd CLN MINUS BIAS OUTPUT (for Environment no.4)
[Initial Value]: 123
[Setup Range]: 102~921 (1 Count: -4.888 V)
[Description]:
For 2ND BTR Cleaning Bias setup for each environment
The resistance detection result of remote cannot be reflected
70. 746-961
[NVM Name]: 2nd CLN MINUS BIAS OUTPUT (For Environment no.5, 6)
[PSW Display]: 2nd CLN MINUS BIAS OUTPUT (for Environment no.5, 6)
[Initial Value]: 123
[Setup Range]: 102~921 (1 Count: -4.888 V)
Chapter 3 Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-c401

Table of Contents