Panasonic DP-C321 Service Handbook page 306

Digital color imaging system
Table of Contents

Advertisement

3-232
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: SIDE REGI adjustment of 4TRAY
57. 742-079
[NVM Name]: ADJUST SIDE REGI TrayModuleAll
[PSW Display]: ADJUST SIDE REGI TrayModuleAll
[Initial Value]: 25
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: SIDE REGI adjustment of 2, 3, 4TRAY (Batch adjustment)
58. 742-083
[NVM Name]: PAPER THE REST TTM-1
[PSW Display]: PAPER THE REST TTM-1
[Initial Value]: 0
[Setup Range]: 0~4000
[Description]: Saves the Cumulative LIFT UP Time from TRAY insertion (For
remaining detection calculation as=A).
59. 742-084
[NVM Name]: PAPER THE REST TTM-2
[PSW Display]: PAPER THE REST TTM-2
[Initial Value]: 0
[Setup Range]: 0~12000
[Description]: Saves the Cumulative LIFT UP Time from TRAY insertion (For
remaining detection calculation as=A).
60. 742-085
[NVM Name]: PAPER THE REST TTM-3
[PSW Display]: PAPER THE REST TTM-3
[Initial Value]: 0
[Setup Range]: 0~15000
[Description]: Saves the Cumulative LIFT UP Time from TRAY insertion (For
remaining detection calculation as=A).
61. 742-086
[NVM Name]: PAPER THE REST 1TM-1
[PSW Display]: PAPER THE REST 1TM-1
[Initial Value]: 0
[Setup Range]: 0~4000
[Description]: Saves the Cumulative LIFT UP Time from TRAY insertion (For
remaining detection calculation as=A).
62. 742-087
[NVM Name]: OCT Availability
[PSW Display]: OCT Condition
[Initial Value]: 1
[Setup Range]: 0~1
[Description]: 0: Not available, 1: Available
63. 742-088
[NVM Name]: Dup On Timing (From Regi Start) (MF)
[PSW Display]: Dup On Timing (From Regi Start) (MF)
[Initial Value]: 20
[Setup Range]: 0~40 (1 Count: 1.31136 ms)
[Description]: Synchronize adjustment to be same as the Regi Clutch at Regi Start
(Double Speed)
64. 742-096
[NVM Name]: PRE T/A START TIMING TTM-2
[PSW Display]: PRE T/A START TIMING TTM-2
[Initial Value]: 139
[Setup Range]: 0~215 (1 Count: 1.31136 ms)
[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
(457~957 ms)
65. 742-097
[NVM Name]: PRE T/A START TIMING TTM-3
[PSW Display]: PRE T/A START TIMING TTM-3
[Initial Value]: 139
[Setup Range]: 0~215 (1 Count: 1.31136 ms)
[Description]: Adjusts the Time between PRE T/A Starts and Standard Signal (IOT)
(431~931 ms)
66. 742-101
[NVM Name]: MAIN FEED START TIMING TTM-2
[PSW Display]: MAIN FEED START TIMING TTM-2
[Initial Value]: 38
[Setup Range]: 0~83 (1 Count: 1.31136 ms)
[Description]: Adjust the Time between the MAIN FEED Starts and the PRE T/A
(780~1280 ms).
67. 742-102
[NVM Name]: MAIN FEED START TIMING TTM-3
[PSW Display]: MAIN FEED START TIMING TTM-3
[Initial Value]: 38