10. 700-086
[NVM Name]: SMB: Spool Off
[PSW Display]: SMB Buffer Size
[Initial Value]: 256 KB
[Setup Range]: 64*1024~1*1024*1024
[Read/Write]: Read/Write
[Description]: 64 KB~1 MB (32 KB interval)
11. 700-087
[NVM Name]: IPP: Spool Off
[PSW Display]: IPP Buffer Size
[Initial Value]: 256 KB
[Setup Range]: 64*1024~1*1024*1024
[Read/Write]: Read/Write
[Description]: 64 KB~1 MB (32 KB interval)
12. 700-088
[NVM Name]: Salutation
[PSW Display]: Salutation Buffer Size
[Initial Value]: 256 KB
[Setup Range]: -
[Read/Write]: Read/Write
[Description]: 64 KB~1 MB (32 KB interval)
13. 700-089
[NVM Name]: HDD Availability
[PSW Display]: HDD Status
[Initial Value]: -
[Setup Range]: -2~0
[Read/Write]: Read
[Description]: 0: Yes, -1: Error, -2: No (Auto Detect)
14. 700-120
[NVM Name]: Time Zone
[PSW Display]: Time Zone
[Initial Value]: 540
[Setup Range]: -
[Read/Write]: Read/Write
[Description]: Displays the Time difference from GMT. E.g. Japan: 540, Hawaii: -600
15. 700-124
[NVM Name]:
3-295
Auto Clear Timer
(Combining Auto Resume Timer, Auditron Off Timer and Tools Off Timer)
[PSW Display]: Auto Clear Timer
[Initial Value]: 1 min
[Setup Range]: 0~240
[Read/Write]: Read/Write
[Description]:
MF: 0, 1~4 : [Disable (0), 1~4 min] (in increments of 1min)
P: 0, 1~30: [Disable (0), 1~30 min] (in increments of 1min)
16. 700-125
[NVM Name]: Job Cancel Timer
[PSW Display]: Job Cancel Timer
[Initial Value]: 10 min
[Setup Range]: 0~5940
[Read/Write]: Read/Write
[Description]:
0: Disable
240~5940: 4~99 min (in increments of 1 min)
(The MF-UI SOD has a different value. This value is abstracted from the COPY SOD)
17. 700-126
[NVM Name]: Operating Timer
[PSW Display]: Operating Timer
[Initial Value]: 10 sec
[Setup Range]: 0~240
[Read/Write]: Read/Write
[Description]:
0: Disable
1~240 : [1~240 sec] (in increments of 1sec)
18. 700-127
[NVM Name]: Job End Timer
[PSW Display]: Job End Timer
[Initial Value]: 6 sec
[Setup Range]: 0~240
[Read/Write]: Read/Write
[Description]:
0: Disable
1~240 : [1~240 sec] (in increments of 1 sec)
Chapter 3 Troubleshooting