[Simultaneous Output Items]: Off
[Operation Description]: Monitors reflective ratio on the belt of ADC_Sensors by a
specific interval.
20. 009-256
TEMP Sensor
[PSW Display]: TEMP Sensor
[Component Type]: IN
[Simultaneous Output Items]: Off
[Operation Description]: Monitors temperature sensor by a specific interval.
21. 009-257
HUM Sensor
[PSW Display]: HUM Sensor
[Component Type]: IN
[Simultaneous Output Items]: Off
[Operation Description]: Monitors temperature sensor by a specific interval.
22. 010-100
STS Front Temperature
[PSW Display]: STS Front Temperature
[Component Type]: IN
[Simultaneous Output Items]:
[Operation Description]:
Displays the average value calculated from the formula below using the
temperature AD value obtained from the front Thermister.
Average value = (Previous average value + Temperature AD value obtained from
Thermister) /2
23. 010-101
STS Rear Temperature
[PSW Display]: STS Rear Temperature
[Component Type]: IN
[Simultaneous Output Items]: Off
[Operation Description]:
Displays the average value calculated from the formula below using the
temperature AD value obtained from the rear Thermister.
Average value = (Previous average value + Temperature AD value obtained from
Thermister) /2