60. 752-130
[NVM Name]: Set ATC Control Nominal Value [0] [Y]
[PSW Display]: Set ATC Control Nominal Value [0] [Y]
[Initial Value]: 592
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
61. 752-131
[NVM Name]: Set ATC Control Nominal Value [0] [M]
[PSW Display]: Set ATC Control Nominal Value [0] [M]
[Initial Value]: 592
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
62. 752-132
[NVM Name]: Set ATC Control Nominal Value [0] [C]
[PSW Display]: Set ATC Control Nominal Value [0] [C]
[Initial Value]: 592
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
63. 752-133
[NVM Name]: Set ATC Control Nominal Value [0] [K]
[PSW Display]: Set ATC Control Nominal Value [0] [K]
[Initial Value]: 602
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
64. 752-134
[NVM Name]: Set ATC Control Nominal Value [1] [Y]
[PSW Display]: Set ATC Control Nominal Value [1] [Y]
[Initial Value]: 632
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
65. 752-135
[NVM Name]: Set ATC Control Nominal Value [1] [M]
3-257
[PSW Display]: Set ATC Control Nominal Value [1] [M]
[Initial Value]: 632
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
66. 752-136
[NVM Name]: Set ATC Control Nominal Value [1] [C]
[PSW Display]: Set ATC Control Nominal Value [1] [C]
[Initial Value]: 632
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
67. 752-137
[NVM Name]: Set ATC Control Nominal Value [1] [K]
[PSW Display]: Set ATC Control Nominal Value [1] [K]
[Initial Value]: 642
[Setup Range]: 0~1023
[[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
68. 752-138
[NVM Name]: Set ATC Control Nominal Value [2] [K]
[PSW Display]: Set ATC Control Nominal Value [2] [K]
[Initial Value]: 562
[Setup Range]: 0~1023
[Description]: ATC Control Nominal Value before environment/deterioration
correction as center setup
69. 752-156
[NVM Name]: ATC Control Nominal Value [Y]
[PSW Display]: ATC Control Nominal Value [Y]
[Initial Value]: 500
[Setup Range]: 0~1023
[Description]:
[Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC
Deterioration Correction Value]+[ATC Nominal Value OFFSET]
70. 752-157
[NVM Name]: ATC Control Nominal Value [M]
[PSW Display]: ATC Control Nominal Value [M]
[Initial Value]: 500