3-246
[Description]:
For 2ND BTR Cleaning Bias setup for each environment
The resistance detection result of remote cannot be reflected
71. 746-962
[NVM Name]: 2nd CLN MINUS BIAS OUTPUT (For Environment no.7, 8, 9)
[PSW Display]: 2nd CLN MINUS BIAS OUTPUT (for Environment no.7, 8, 9)
[Initial Value]: 123
[Setup Range]: 102~921 (1 Count: -4.888 V)
[Description]:
For 2ND BTR Cleaning Bias setup for each environment
The resistance detection result of remote cannot be reflected
72. 746-963
[NVM Name]: Y Offset Distance
[PSW Display]: Y offset distance
[Initial Value]: 16
[Setup Range]: 0~16 (1 Count: 1 ms)
[Description]: Distance of 0ms~39 ms between Drum contact and 1ST BTR
73. 746-964
[NVM Name]: M Offset Distance
[PSW Display]: M offset distance
[Initial Value]: 16
[Setup Range]: 0~16 (1 Count: 1 ms)
[Description]: Distance of 0ms~39 ms between Drum contact and 1ST BTR
74. 746-965
[NVM Name]: C Offset Distance
[PSW Display]: C offset distance
[Initial Value]: 16
[Setup Range]: 0~16 (1 Count: 1 ms)
[Description]: Distance of 0ms~39 ms between Drum contact and 1ST BTR
75. 746-966
[NVM Name]: K Offset Distance
[PSW Display]: K offset distance
[Initial Value]: 16
[Setup Range]: 0~16 (1 Count: 1 ms)
[Description]: Distance of 0ms~39 ms between Drum contact and 1ST BTR
76. 746-967
[NVM Name]: 1st BTR Vmonitor Y
[PSW Display]: 1st BTR Vmonitor Y
[Initial Value]: 36
[Setup Range]: 4~178 (1 Count: 28.01 V)
[Description]: Displays the voltage at primary transfer resistance detection
(100~5000V)
77. 746-968
[NVM Name]: 1st BTR Vmonitor M
[PSW Display]: 1st BTR Vmonitor M
[Initial Value]: 36
[Setup Range]: 4~178 (1 Count: 28.01 V)
[Description]: Displays the voltage at primary transfer resistance detection
(100~5000V)
78. 746-969
[NVM Name]: 1st BTR Vmonitor C
[PSW Display]: 1st BTR Vmonitor C
[Initial Value]: 36
[Setup Range]: 4~178 (1 Count: 28.01 V)
[Description]: Displays the voltage at primary transfer resistance detection
(100~5000V)
79. 746-970
[NVM Name]: 1st BTR Vmonitor K
[PSW Display]: 1st BTR Vmonitor K
[Initial Value]: 36
[Setup Range]: 4~178 (1 Count: 28.01 V)
[Description]: Displays the voltage at primary transfer resistance detection
(100~5000V)
80. 746-971
[NVM Name]: Plain paper A~G 104mm/BW side1
[PSW Display]: Remote for Plain paper A ~G Normal speed BW Side1
[Initial Value]: 100
[Setup Range]: 0~200 (1 Count: 1 %)
[Description]:
For Secondary Transfer output adjustment of Plain paper A ~G 104mmsec side1 BW.
Displays the multiplication value in secondary transfer resistance calculation
result of 746-006.
ex
At 100: Secondary Transfer Voltage=245x-4.888x1.0=-1200 V
At 150: Secondary Transfer Voltage=245x-4.888x1.5=-1800 V