ADJ1. 1. 3 DC922 TRC Control

Purpose To check that the output of ATC Sensor and TC Control performed normally. Provides
the TONE UP/DOWN function (calculates the increase and decrease of the toner by the difference
of the ATC Sensor output and standard value, or performing UP/DOWN by inputting the value
manually) as a restoring function when TC does not operate normally.
• Check that LTR paper (LEF) is loaded in Tray 1 since TONE UP/DOWN uses
paper.
• Do not put a value in the DC922 TRC Control, if the ATC Sensor Failure
09-380~09-383 occurs, when the value for DC131 [752-324] (SW_DispMODE) is
set "0".
To enter the Diag, change the value of DC131 [752-324](SW_DispMODE] to either
of "1, 2" and execute this Diag.
When completing the operation after the ATC Sensor (UI screen indicates
"ATC_OK") turns normal, return the value of DC131 [752-324](SW_DispMODE)
to "0" (Normal Mode).
*When using the abnormal ATC Sensor temporarily, keep the value "1, 2".
• The relations between the value of DC131 [752_324] (SW_DispMODE) and the
DISP Mode are described in the table below.
Value of DC131 [752-324]
(SW_DispMODE)
0
1
2
Chapter 2 Maintenance
Disp Mode
ATC+ICDC Mode (Normal Mode)
ICDC MODE
Timer Disp Mode