8-1-2. S Tension Regulator Operating Position Adjustment
Note
When the S-tension regulator band assembly and the S reel table assembly is
replaced, be sure to perform the S tension regulator operating position adjustment.
Preparations
1. Turn off the main power.
2. Remove the front lid and the outside panel assembly. (Refer to Section 1-4.)
Tools
. Torque screwdriver bit (for M2) :
. Torque screwdriver (for 3 kg) :
Check Procedure
1. Setting up the mode
Rotate the manual eject gear (A) counter-clockwise until the unit reaches the
threading-end state.
(Refer to Section 7-1-4.)
HDW-750/750CE V1
J-6325-380-A
J-6325-400-A
8-1. Mechanical Adjustment