7-18. (S) Soft Brake Assembly Replacement
7-18. (S) Soft Brake Assembly Replacement
Overview
Replacement
Removing the (S) soft brake assembly replacement
Installing the (S) soft brake assembly replacement
Adjustment after replacement
Capstan add-on recording adjustment
Note
If a tape hunts or slackens during the REW mode, replace the (S) soft brake assem-
bly.
Preparations
1. Turn off the main power.
2. Remove the front lid and outside panel assembly. (Refer to Section 1-4.)
3. Remove the cassette compartment. (Refer to Section 1-9.)
4. Check that the unit is in the unthreading-end state.
Tools
. Cleaning cloth : 3-184-527-01
. Cleaning fluid : 9-919-573-01
Removal
1. Removing the (S) soft brake assembly
replacement
Remove the two precision screws and the (S) soft
brake assembly.
7-66
Precision screws
P1.4 x 3.5
(S) soft brake
assembly