Sony HDW-750 Maintenance Manual page 149

Hd camcorder
Hide thumbs Also See for HDW-750:
Table of Contents

Advertisement

BLK GAMMA Display (Adjusting black gamma)
? 05
O
BLK GAMMA
BLACK GAMMA
BLK GAMMA RANGE :
MASTER BLK GAMMA:
R BLK GAMMA
G BLK GAMMA
B BLK GAMMA
OUTPUT SELECT
Item
BLACK GAMMA
BLK GAMMA RANGE
MASTER BLK GAMMA
R BLK GAMMA
G BLK GAMMA
B BLK GAMMA
OUTPUT SELECT
*1 : RGB can be selected only when the Camcorder is used in the service mode.
HDW-750/750CE V1
:
OFF
HIGH
0
:
0
:
0
:
0
:
Y
Setting
OFF/ON
LOW/L.MID/H.MID/HIGH
(_99 to 99)
(_99 to 99)
(_99 to 99)
(_99 to 99)
Y/R/G/B/RGB
*1
Function
Turns ON/OFF the black gamma correction function.
Sets the range in which the black gamma correction is
effective.
LOW : 0 to 3.6 %
L.MID : 0 to 7.2 %
H.MID : 0 to 14.4 %
HIGH : 0 to 28.8 %
Adjusts the master black gamma correction curve.
Adjusts the R black gamma correction curve.
Adjusts the G black gamma correction curve.
Adjusts the B black gamma correction curve.
Selects the video signal that is output from the TEST
OUT and the VBS/SDI OUT terminal.
(The Y-signal becomes the VBS signal when the
REAR BNC OUT SEL of the OUTPUT SEL display of
the OPERATION menu selects the VBS position and
when the TEST OUT SELECT chooses the SD
position.) The output signal returns to the Y-signal
without fail at power-on.
4-5. PAINT Menu
4-27