Installation
2. Installing the manual eject assembly
Install the new compression (coil) (ST) spring
and the new manual eject assembly into the
mount shaft and fix it with precision screw.
The standard tightening torque value :
_2
10 x 10
N.m (1 kgf.cm)
3. Operation check
(1) Check that the manual eject gear (A) returns
when it is pressed once and then depressed.
(2) Push in the manual eject gear (A) and then
rotate it. Check that it moves smoothly.
HDW-750/750CE V1
7-20. Manual Eject Assembly Replacement
Manual eject gear (A)
Manual eject
assembly
Compression (coil)
(ST) spring
Mount shaft
Precision screw
P1.4 x 3.5
7-71