4-4. OPERATION Menu
When M.INT is selected in LOOP/INTVAL REC
LOOP/INTVAL REC : M.INT
NUMBER OF FRAME :
TRIGGER INTERVAL:
PRE-LIGHTING
Item
Setting
NUMBER OF FRAME
1/2/4/8
*1
TRIGGER INTERVAL
M/1SEC/2SEC/3SEC/4SEC/5SEC/
6SEC/7SEC/8SEC/9SEC/10SEC
20SEC/30SEC/40SEC/50SEC
1MIN/2MIN/3MIN/4MIN/5MIN/6MIN/
7MIN/8MIN/9MIN/10MIN/15MIN/20MIN/
30MIN/40MIN/50MIN/1H/2H/3H/4H/6H/
12H/24H
PRE-LIGHTING
OFF/2SEC/5SEC/10SEC
*1 : This item is displayed only when the unit of which the ROM version of the AT board is 1.40 and higher. You can check the AT
version by the ROM VERSION display in the DIAGNOSIS menu.
4-8
1
5MIN
:
OFF
Function
Sets the number picture frames that are
recorded by one time of recording in the
Manual Interval REC.
Displayed only when M.INT is selected in the
above LOOP/INTVAL REC.
Sets the interval time.
When "M" is set, number of frames that are
specified at the moment of pressing the REC
switch manually, are recorded.
When any specific time is set, numbers of the
specified frames are recorded that is triggered
by the REC switch.
Sets the function of turning on the light
automatically during the Manual Interval REC.
This is the function to set the timing how many
seconds before starting recording, the light
turns on.
This item is displayed only when the
A.INT is selected in the afore-mentioned
LOOP/INTVAL REC,or when the M. INT is
selected and the TRIGGER INTERVAL is
other than "M".