3.9 MANUAL DEFROST

HEAT
+34
SETPOINT
DEFROST CYCLE STARTED
When defrost mode cannot be manually initiated "CAN-
NOT START DEFROST CYCLE" is displayed in the
MessageCenter. This will occur when:
DTT is above 40°F (4°C). Defrost may be entered
any time the DTT is below 40°F (4°C) OR
The engine has not run 15 seconds after starting OR
The unit is in PC Mode OR
The unit is in Pretrip OR
There is an active shutdown Alarm.
DEFROST LIGHT
COOL
DEFROST
BOX TEMPERATURE
MANUAL
DEFROST
Press the MANUAL DEFROST key. The DEFROST light will come on and the Messa-
geCenter will display "DEFROST CYCLE STARTED" for 5 seconds, or flash "CANNOT
START DEFROST CYCLE" for five seconds.
ALARM
START‐STOP
dF
ALARM LIST
START‐STOP/
CONTINUOUS
The Manual Defrost Key can be used at any
time to start a Defrost Cycle as long as the pre-
ceding conditions are met.
Refer to Section 4.6 for more detailed informa-
tion on DEFROST.