10.Use
tool
(Carrier
07-60083-00) to lock the engine flywheel
11
14
11. Pull the harness on the top of generator out of the
way.
12.Swing out the engine.
13.Remove the fan cover (4 bolts)
14.Remove the fan blade center screw. Using two 6mm
bolts and a puller, remove the blade. NOTE: DO
NOT use 6mm bolts to drive the fan off.
CAUTION
A mica shim (Carrier Transicold part num-
ber 54-00630-25) must be installed before
removal of the generator. The generator is
to be removed as one piece, with the shim in
place. DO NOT attempt to remove the rotor
from the stator.
10
Transicold
part
number
13
Do not remove and use the shim from a replace-
ment generator, the replacement generator
shim must remain in place until the generator is
installed.
18
15
15.Remove 3 of the 6 flywheel bolts on the generator.
16.Insert 3 guiding rods (P/N : SKM 5671.)
17.Place the mica shim (P/N 54-00630-25) between the
rotor and the stator prior to loosening any other bolts.
18.Remove the last 3 flywheel bolts.
21
20
19
19.Install the lifting tool (Carrier Transicold part number
07-60085-01).
20.Remove the remaining stator bolts.
21.Remove the generator with a sling. DO NOT pry
against the spacer between engine and generator.
8−39
NOTE
17
19
62-11389