Carrier VECTOR 6500 Operation & Service Manual page 68

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

* Displays information or setting entered in the microprocessor Configurations
+ May or may not be displayed depending on Parameter/Configuration settings
*
PRODUCTSHIELD SETUP:
+
S PRODUCTSHIELD
ECONO:
SS
ECONO MIN
TEMP - XX°
SS
ECONO MAX
TEMP - XX°
SS
ECONO
DELTA-T - XX°
S PRODUCTSHIELD
HIGH AIR:
SS
HIGH AIR MIN
TEMP - XX°
SS
HIGH AIR MAX
TEMP - XX°
SS
HIGH AIR
DELTA-T - XX°
S PRODUCTSHIELD:
WINTER - XX°
*
RANGE 1 LOCK
+
*
RANGE 1 MINIMUM TEMP
+
*
RANGE 1 MAXIMUM TEMP Displays maximum temperature setting for Range 1. (Will only be dis-
+
*
RANGE 2 LOCK
+
*
RANGE 2 MIN. TEMP
+
*
RANGE 2 MAX. TEMP
+
*
TEMPERATURE (REMOTE)
SENSOR (1, 2 or 3)
+
*
DATALOGGER (DataLink
data recorder)
Table 3-1. Unit Data - Continued
Press "=" to access the list.
Indicates if ProductShield Econo is OFF OR Go To Start-Stop OR Go
To Continuous Run
Displays minimum temperature setting for activation of ProductShield
Econo. (Will only be displayed if Econo is NOT OFF)
Displays maximum temperature setting for activation of ProductShield
Econo. (Will only be displayed if Econo is NOT OFF)
Displays Delta-T setting for activation of ProductShield Econo. (Will only
be displayed if Econo is NOT OFF)
Indicates if ProductShield High Air is OFF OR ON
Displays minimum temperature setting for activation of ProductShield
High Air. (Will only be displayed if Econo is NOT OFF)
Displays maximum temperature setting for activation of ProductShield
High Air. (Will only be displayed if Econo is NOT OFF)
Displays Delta-T setting for activation of ProductShield High Air. (Will
only be displayed if Econo is NOT OFF)
Indicates ProductShield Winter is OFF or the ambient temperature below
which ProductShield Winter will be active.
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 1 Lock is turned off.
CONTINUOUS = When the set point is set between Range 1 Minimum
& Maximum Temperatures, the unit is set to operate only in Continuous.
START-STOP - When the set point is set between Range 1 Minimum &
Maximum Temperatures, the unit is set to operate only in Start-Stop.
Displays minimum temperature setting for Range 1. (Will only be dis-
played if Range Lock 1 is ON)
played if Range Lock 1 is ON)
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 2 Lock is turned off.
CONTINUOUS = When the set point is set between Range 2 Minimum
& Maximum Temperatures, the unit is set to operate only in Continuous
Run.
START-STOP = When the set point is set between Range 2 Minimum &
Maximum Temperatures, the unit is set to operate only in Start-Stop.
Displays minimum temperature setting for Range 2. (Will only be dis-
played if Range Lock 2 is ON)
Displays maximum temperature setting for Range 2. (Will only be dis-
played if Range Lock 2 is ON)
Will only display when one or more of the optional sensors are con-
figured ON. Displays temperate reading of remote Temperature Sensor 1
(2, or 3).
Displays the current Date and Time that the DataLink data recorder is
using. This may be different than local time, depending on the Time
Zone and Daylight Savings.
3−19
62-11389