Configuration
DISPLAY STANDBY RUN HR
DISPLAY TOTAL SWITCH ON HR
DIESEL RESET VALUE
(Refer to Table 8−1 for oil/filter
change intervals.)
STANDBY RESET VALUE
SWITCH ON RESET VALUE
PM 1 - 5 (Preventative Maintenance
Hour Meters)
62-11389
Table 5−2 Microprocessor Configurations - Continued
Selections
YES / NO
YES / NO
0FF
50 TO 30,000
hours in 50 hour in-
crements
0FF
50 TO 30,000
hours in 50 hour in-
crements
0FF
50 TO 30,000
hours in 50 hour in-
crements
OFF
ENGINE
PROTECT
HOURS
SWITCH ON
PROTECT
HOURS
STANDBY HOURS
START CYCLES
HIGH SPEED
HOURS
COMPRESSOR
RUN HOURS
MAINTENANCE
DAYS
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour
meter menu.
NO = This hour meter will not be displayed during
the startup messaging sequence. It will be dis-
played with the "other meters and counters".
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour
meter menu.
NO = This hour meter will not be displayed during
the startup messaging sequence. It will be dis-
played with the "other meters and counters".
When the engine maintenance hour meter is reset,
the value selected here will be added to the to the
present meter reading to indicate to the micropro-
cessor when the next service interval alarm will be
activated. If the value entered is "0" the alarm fea-
ture is turned off.
When the standby maintenance hour meter is reset,
the value selected here will be added to the to the
present meter reading to indicate to the micropro-
cessor when the next service interval alarm will be
activated. If the value entered is "0" the alarm fea-
ture is turned off.
When the switch on maintenance hour meter is re-
set, the value selected here will be added to the to
the present meter reading to indicate to the micro-
processor when the next service interval alarm will
be activated. If the value entered is "0" the alarm
feature is turned off.
OFF = This selection will turn this meter OFF (will
not display).
ENGINE HOURS = this meter will count the engine
hours until the next reset interval.
SWITCH ON HOURS = this meter will count the
switch on hours until the next reset interval.
STANDBY HOURS = this meter will count the
standby hours until the next reset interval.
START CYCLES = this meter will count how many
times the engine has started until the next reset
interval.
HIGH SPEED HOURS = this meter will count the
number of hours the engine operated in high speed
until the next reset interval.
COMPRESSOR RUN HOURS = this meter will
count the number of hours the compressor has op-
erated until the next reset interval.
MAINTENANCE DAYS = this meter will count the
number of days until the next reset interval.