3.3 SELF TEST

MODE LIGHTS
MAIN DISPLAY
MessageCenter
DOOR
When first powered up, the microprocessor will run a
self test consisting of the following steps:
All of the mode lights will illuminate.
All of the segments on the main display will turn on.
All of the liquid crystal diodes (LCDs) of the Messa-
geCenter will turn on to verify their operation.
The main display will then display the set point tem-
perature in the left characters and a compartment
(BOX) temperature in the right characters. The char-
acter just to the right of the box temperature indi-
cates the temperature units as "C" Centigrade or "F"
Fahrenheit.
The MessageCenter will then display "MICRO SELF
TEST IN PROGRESS" for several seconds.
If one or more Inactive alarms are stored, "INAC-
TIVE ALARMS IN MEMORY" will be displayed and
the Alarm LED will flash for 5 seconds, then turn off.
Refer to Section 3.12 for information on viewing in-
active alarms.
62-11389
SELF TEST
. If the IntelliSet option has been installed the name of
the current IntelliSet or "INTELLISET OFF" will be
displayed. Refer to Section 3.17 for IntelliSet inform-
ation.
If the microprocessor has been configured to display
the hour meters, the Total Engine Hours, Standby
Run Hours and/or Total Switch On Hours will be
displayed.
If there are one or more active alarms, the Mes-
sageCenter will display "UNIT SHUTDOWN - SEE
ALARM LIST". Any active alarms must be corrected
and cleared before the unit can start. Refer to Sec-
tion 3.11 for information on active alarms.
The microprocessor will then display "SMV CLOS-
ING" while the CSMV and the EVXV are brought to
unit starting positions.
In engine operation, the intake air heater will ener-
gize (as required), the buzzer will sound, and the en-
gine will start.
In standby operation, the buzzer will sound then
the fans and compressor will start.
3−4
ENGINE
OFF
STANDBY

Hide quick links:

Advertisement

Table of Contents
loading