3.8 SLEEP MODE

HEAT
SLEEP MODE SETTINGS
Entering using Functional Parameter settings:
1. Press the SELECT key until the MessageCenter displays "PRESS ↑↓ TO VIEW SETTINGS".
2. Press the UP ARROW key until the Functional Parameter "SLEEP MODE SETTINGS" is displayed.
Press the = key. The MessageCenter will then display "↑↓ TO SCROLL, THEN = TO SAVE".
3. Press either the UP or DOWN ARROW key until "SLEEP MODE: YES" is displayed. The MessageCenter
will flash, indicating that this change has not been entered into memory. Press the = key to save the setting
ti memory - the MessageCenter will stop flashing, the unit is now in sleep mode.
4. Additional Functional Parameter sub menu selections for "wake up time" and "run pretrip at wake" will now be
available and may be saved to memory following the key stroke sequence in the preceding step. Refer to the
following paragraphs for information on these settings.
TO EXIT SLEEP MODE
Place the Main Power switch in the OFF position, then back to the desired position.
Sleep Mode is generally used in cold ambients when the
unit will be off for an extended period of time with no
product inside the refrigerated compartment. Many
times units are difficult to start due to a discharged bat-
tery, thickened engine oil, etc. after time in cold ambient.
There is NO TEMPERATURE CONTROL in Sleep
Mode and it should never be used if the compartment
contains perishable or frozen products.
In Sleep Mode and Engine Operation the unit will "Wake
Up" periodically and start the engine to keep the battery
charged and the engine warm.
COOL
DEFROST
SETPOINT
ALARM
START‐STOP
BOX TEMPERATURE
MANUAL
ALARM LIST
START‐STOP/
DEFROST
CONTINUOUS
In Sleep and Standby Mode if the unit is connected to
standby power, the battery charger is energized and will
keep the battery charged. The engine will not run with
the switch in the STANDBY position.
ADDITIONAL SUB MENUS
1. "WAKE UP TIME"
a. When "WAKE UP TIME" is set to NO the unit will
remain in Sleep Mode until it is taken out manually
(refer to "TO EXIT SLEEP MODE" instruction
above).
b. When "WAKE UP TIME" is set to YES the "SET
WAKEUP TIME" menu will become available.
3−11
CONTINUOUS
SELECT