Table 5−2 Microprocessor Configurations - Carrier VECTOR 6500 Operation & Service Manual

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

Configurations are presented at the beginning of the list and progressing using the green UP arrow key
Configuration
UNIT MODEL NUMBER #
UNIT SERIAL NUMBER #
TRAILER ID #
The default display for this Configuration is "TRAILER ID #". The display may be modified if the "UNIT OP-
ERATION'" Configuration is set to "RAIL". If this Configuration is set to "RAIL" then "ASSET ID #" or "CAR ID
#" may display rather than the "TRAILER ID #" default. Refer to the UNIT OPERATION Configuration later in
this table.
SET NEW HOURS
GLOW TIME
OUT OF RANGE SHUTDOWN
PARAMETERS LOCKOUT:
62-11389
Table 5−2 Microprocessor Configurations
NOTE
Selections
Unit Family types,
and then a list of
configurable model
numbers
NOTE
This Configuration will display when a replacement microprocessor is
installed. It allows entry of the hours (from the existing microprocessor)
into replacement microprocessor. This Configuration will only display until
one of the hour meters reaches 25 hours. Changes to these values may
be made for up to 60 minutes.
SHORT
LONG
INTAKE HEATER
YES / NO
YES / NO
5−12
Description
Indicates to the microprocessor the model number
of the unit. There are several model numbers
provided in the list. Scroll to the Vector Family
entries and select the model number printed on the
Model/Serial Number nameplate.
The unit S/N may be entered. This may be up to 10
characters long. Numbers, Letters, and a space are
available by scrolling through the available list.
A customer assigned ID # may be entered. This
may be up to 10 characters long. Numbers, letters,
and spaces may be entered by scrolling through the
available list. After selecting the desired characters,
press SAVE to lock the characters in memory.
Indicates to the microprocessor which engine is in
the system
LONG = Glow Plug equipped and longer glow times
are used (TV engines)
SHORT= Glow Plug equipped and shorter glow
times are used (DI engines)
INTAKE HEATER = Intake Heater equipped (Tier 4
engines).
NOTE: Refer to Table 4−1 for glow times.
YES = When the refrigerated compartment temper-
ature has been out-of-range for 45 minutes, the
alarm light will come on, and the unit will shutdown.
NO = When the refrigerated compartment tempera-
ture has been out-of-range for 30 minutes, the
alarm light will come on and the unit will continue to
run.
Refer to Alarm A53 - "BOX TEMPERATURE OUT
OF RANGE" (Section 7) for more information.
YES = Functional Parameters cannot be changed
using the keypad.
NO = Functional Parameters can be changed using
the keypad, unless individually locked out by Reefer
Manager.