Carrier VECTOR 6500 Operation & Service Manual page 20

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

WARNING
Use the required protective eye wear and
clothing when working with solvents.
WARNING
Beware of moving poly V-belt and belt driv-
en components.
WARNING
When working with belts, beware of pinch
points.
WARNING
Do not use a nitrogen cylinder without a
pressure regulator. Cylinder pressure is
approximately 2350 psig (159.9 bar). Do not
use oxygen in or near a refrigerant system
as
an
explosion
Figure 8−30)
WARNING
Do not unscrew replacement compressor
lifting
eyelet/blankoff
capscrews all the way before breaking seal.
Entrapped pressure could result in injury.
WARNING
Do not unscrew cylinder head mounting
capscrews all the way before breaking seal.
Entrapped pressure could result in injury.
WARNING
Do not unscrew unloader enclosing tube
nut all the way before breaking seal.
Entrapped pressure could result in injury.
WARNING
Do not unscrew unloader valve body
mounting bolts all the way before breaking
seal. Entrapped pressure could result in
injury.
may
occur.
(See
plate
mounting
Do not direct water or steam into the gener-
ator openings. Do not allow any soap and
water solutions to enter the generator.
Generators of this type should not be
"flashed." Operation with external voltage
source or momentary shorting of leads will
damage the generator and may cause in-
jury.
Under no circumstances should anyone at-
tempt to repair the keypad, display or in-
ternal control module components. Should
a problem develop with these components,
contact your nearest Carrier Transicold
dealer for replacement.
Use only ethylene glycol anti-freeze (with
inhibitors) in system as glycol by itself will
damage the cooling system. Always add
pre-mixed 50/50 anti-freeze and water to ra-
diator / engine. Never exceed more than a
60% concentration of anti-freeze. Use a low
silicate anti-freeze meeting GM specifica-
tions GM 6038M for standard life coolant or
use Texaco Havoline extended life coolant
or any other extended life coolant which is
Dexcool approved and has 5/150 (5 years /
150,000 miles) on the label.
Service Mode MUST be used whenever re-
moving refrigerant charge, refrigerant leak
checking or evacuating.
The display and MessageCenter may be-
have differently during the software loading
process, depending on the version of soft-
ware currently in the microprocessor. DO
NOT INTERRUPT THE SOFTWARE INSTAL-
LATION PROCESS ONCE IT HAS STARTED.
Also, do not place the Main Power switch in
the OFF position during the initial power up
following a software upgrade.
1−3
WARNING
WARNING
CAUTION
CAUTION
CAUTION
CAUTION
62-11389