3.1 STARTING - ENGINE OPERATION

Advance microprocessor equipped units may start automatically at any time the Main Power switch
is not in the OFF position. Also, the unit may be fitted with two way communication equipment that
will allow starting of the unit from a remote location even though the switch is in the OFF position.
Be aware of HIGH VOLTAGE supplied at the power plug or from the generator. When performing ser-
vice or maintenance procedures: ensure any two way communication is disabled in accordance with
the manufacturer's instruction, ensure the Main Power Switch is in the OFF position and, whenever
practical, disconnect the high voltage source, lockout/tagout the receptacle and disconnect the neg-
ative battery connection. NEVER dis-assemble the generator: HIGH MAGNETIC FIELD INSIDE! This
field can interfere with cardiac implants such as pacemakers and defibrillators.
Under no circumstances should ether or any other starting aids be used to start engine.
MODE LIGHTS
-20.0
KEYPAD DOOR
UNITS WITH A MAIN POWER SWITCH LABELED
ENGINE/OFF-STANDBY
1. Place the Main Power switch in the ENGINE po-
sition.
The microprocessor will perform a Self Test
2.
(refer to Section 3.3) and then start the unit
automatically.
SECTION 3
OPERATION
WARNING
WARNING
WARNING
MAIN DISPLAY
SWITCH BOARD
+34.5 F
MessageCenter
ENGINE
OFF
STANDBY
UNITS WITH A MAIN POWER SWITCH LABELED
START/RUN-OFF
1. Place the Main Power switch in the ENGINE posi-
tion. Then place the switch labeled START/
RUN-OFF in the START/RUN position.
The microprocessor will perform a Self Test
2.
(refer to Section 3.3) and then start the unit
automatically.
3−1
ALTERNATE
CONFIGURATION
STANDBY
ENGINE
I
START/RUN
O
OFF
Main Power
Switches
62-11389