Message
PRETRIP FAIL & COMPLETED
PRETRIP FAIL IN TEST XX
PRETRIP PASS
PRETRIP STOPPED BY USER
PRODUCTSHIELD: ECONO ON
PRODUCTSHIELD: HIGH AIR ON
PRODUCTSHIELD: WINTER ON
READY TO INSTALL SOFTWARE
RECOVER / LEAK CHK / EVAC MODE
REMOVE CARD - BATTERY TOO LOW
REMOTE SWITCH 1 (2) OPEN
REMOTE SWITCH 1 (2) OPEN - LOW
SPEED
REMOVE JUMPER
SAME SW, = TO LOAD, ↑ TO CANCEL
SERVICE MODE
SETPOINT CHANGED
SETPOINT NOT CHANGED
SETTING SMV: XXX %
SLEEP MODE, OFF / ON TO WAKE
SLEEP WARNING: DOOR OPEN
SLEEP WARNING: NO TEMP CONTROL
SLEEP WARNING: REMS1(2) OPEN
SMV CLOSING: WAIT XXX SECONDS
MessageCenter MESSAGES - Continued
The Pretrip test is completed, and some of the Pretrip tests did not
pass. Check the Alarm List for Pretrip alarms.
Some of the Pretrip tests did not pass and the Pretrip was not com-
pleted. Check the Alarm List for Pretrip alarms.
All of the Pretrip tests were ok.
Pretrip has been stopped by user.
The unit is operating in ProductShield Econo which overrides nor-
mal unit Start-Stop or Continuous Run operation. Refer to Section
4.7.3.
The unit is operating in ProductShield High Air which overrides nor-
mal unit speed operation. Refer to Section 4.7.3.
The unit is operating in ProductShield Winter which overrides nor-
mal unit operation. Refer to Section 4.7.3.
The microprocessor has been forced into Program Install Mode. If
this message does not clear after loading the current version of
software, check for a shorted circuit between 5MP5 and 5MP6.
This message will be displayed when the unit is in Service Mode
and the system is ready for recovery and leak testing.
If a PC card is inserted when battery is below 7.0 volts this mes-
sage will be displayed until card is removed.
Remote switch is open. May be connected to a refrigerated
compartment door or a remote control switch.
Shows that the remote switch is open and that the unit is running in
low speed. Switch may be connected to a refrigerated compart-
ment door or a remote control switch.
The Configuration/Technician Test Mode has been entered. Re-
move the jumper wire before continuing.
A Program PC Card has been inserted into the PC Card slot and
the program on the PC Card is the same as the program currently
in the microprocessor. Press the = key to reload the same program
or press the UP ARROW key to cancel and remove card.
Selection in Configuration and Technician Test Modes which is
used when servicing the refrigeration system. Refer to Section
5.2.3.
The new set point has been entered (saved into microprocessor
memory), the new set point will be used.
The new set point has NOT been entered (NOT saved into micro-
processor memory), the old set point will be used.
The Main Power Switch has been toggled out of the OFF position
and the CSMV is opening.
The unit is cycled off in Sleep Mode. Place the Main Power switch
in the OFF position, then back to the desired position to wake the
microprocessor up.
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a refrigerated compartment door is open. The unit will start as
needed for Sleep Mode.
The unit is running in Sleep Mode to charge the battery and (in
Engine Operation) warm the engine coolant. It is not running to
provide temperature control.
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a remote switch is open. The switch may be connected to a
refrigerated compartment door or to a remote control switch. The
unit will start as needed for Sleep Mode.
Power Up and the CSMV is closing. XX indicates the number of
seconds remaining until valve is fully closed.
Description
6−5
62-11389