Carrier VECTOR 6500 Operation & Service Manual page 115

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

Configuration
RPM ALARM SHUTDOWN:
LOW PRESSURE SHUTDOWN
S LP SHUTDOWN DELAY
HIGH SUCT PRESS SHUTDOWN
REFRIGERATION SYST SHUT-
DOWN
SUCTION PRESSURE
COMPRESSOR ALARM
SHUTDOWN
(This Configuration is an option, it
will not display if the option is not in-
stalled.)
CURRENT FOR S/S SHUTOFF
Table 5−2 Microprocessor Configurations - Continued
Selections
YES / NO
YES / NO
(0 - 255 seconds in
1 second incre-
ments)
255 SECS
YES / NO
YES / NO
30 PSIG (2.0 BAR)
0 - 50 psig (0 to
3.4 bar)
[in 1 psig (0.1 bar)
increments]
YES / NO
7.0A
1A TO 10A
(in 0.5A incre-
ments)
YES = When the A39 - "CHECK ENGINE RPM"
alarm is activated the alarm light will illuminate and
the engine will shutdown.
NO = When When the A39 - "CHECK ENGINE
RPM" alarm is activated the alarm light will illumin-
ate and the engine will continue to run.
YES = When the A18 - "LOW REFRIGERANT
PRESSURE" alarm is activated the alarm light will
illuminate and the unit will shutdown.
NO = When the A18 - "LOW REFRIGERANT
PRESSURE" alarm is activated the alarm light will
illuminate and the unit will continue to run.
If the Low Pressure Shutdown Configuration is set
to YES, shutdown is to be delayed for this amount
of time after the Low Pressure Shutdown signal is
received.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT
SETTING.
YES = When the A27 - "HIGH SUCTION PRES-
SURE" alarm is activated the alarm light will illumin-
ate and the unit will shutdown.
NO = When the A27 - "HIGH SUCTION PRES-
SURE" alarm is activated the alarm light will illumin-
ate and the unit will continue to run.
YES = When the A28 - "CHECK REFRIGERATION
SYSTEM" alarm is activated the alarm light will illu-
minate and the unit will shutdown.
NO = When the A28 - "CHECK REFRIGERATION
SYSTEM" alarm is activated the alarm light will illu-
minate and the unit will continue to run.
Pressure to maintain if discharge pressure trans-
ducer is opened or shorted.
If the "Compressor Alarm Shutdown" option has
been installed (refer to Unit Data), this setting will
be available.
YES = The unit will shutdown and not restart when
alarm A13, A17, A18, A27, A28 or A56 activate 3
times within 2 hours of continuous engine opera-
tion.
NO = Normal shutdown rules for above alarms.
In Start-Stop Operation the charging current must
drop below this value before the unit is allowed to
shutdown.
5−13