Carrier VECTOR 6500 Operation & Service Manual page 123

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

Configuration
REMS1 (Remote Switch 1)
OR
REMS2 (Remote Switch 2)
NOTE
If the configuration is set for a
switch, not for a panel, the following
sub configuration will also be avail-
able.
• REMS1
OR
• REMS2
SET TIME
• MONTH
• DAY
• YEAR
• HOURS
• MINUTES
Table 5−2. Microprocessor Configurations - Continued
Selections
NOT INSTALLED
DOOR OPEN
SWITCH OPEN
DOOR OPEN
SWITCH CLOSED
SWITCH ON
CONTACTS OPEN
SWITCH ON
CONTACTS
CLOSED
REMOTE PANEL
ALARM ONLY
UNIT SHUTDOWN
LOW ENGINE
SPEED
DATA RECORDER
ONLY
Indicates to the microprocessor the time and date for the DataLink data
recorder Real Time Clock .
1-12
1-31
1998 - 2037
0-23
0-59
Switch not installed = There is no remote switch or
panel.
DOOR OPEN SWITCH OPEN = The remote switch
will be used as a door switch. The switch contacts
will be OPEN whenever the door is OPEN.
DOOR OPEN SWITCH CLOSED = The remote
switch will be used as a door switch. The switch
contacts will be CLOSED whenever the door is
OPEN.
SWITCH ON CONTACTS OPEN = The remote
switch will be used as a remote control switch. The
switch contacts will be OPEN whenever the switch
is in the ON position.
SWITCH ON CONTACTS CLOSED = The remote
switch will be used as a remote control switch. The
switch contacts will be CLOSED whenever the
switch is ON.
REMOTE PANEL = If set to this value, the remote
panel SYSTEM ON/OFF key will be enabled. The
switch panel mounted Main Power Switch must be
toggled out of the OFF position and the remote
panel SYSTEM ON/OFF key must be pressed for
the unit to operate. However, if the Override Re-
mote Switch 1 or 2 Functional Parameter is set to
YES, the remote panel is disabled.
ALARM ONLY = When the switch is activated, a
warning alarm will be displayed in the Message-
Center.
UNIT SHUTDOWN = When the switch is activated,
a warning alarm will be displayed in the Message-
Center, and the unit will shutdown.
LOW ENGINE SPEED = When the switch is activ-
ated, the engine will be forced to low speed.
DATA RECORDER ONLY = The DataLink data re-
corder will record every time the the switch is activ-
ated. There will be no alarms or messages dis-
played in the MessageCenter.
Select the correct month of the year.
Select the correct day of the month.
Select the correct year.
Select the correct hour (0-11 is AM / 12-23 is PM)
Select the correct minute.
5−21
Description
62-11389