Carrier VECTOR 6500 Operation & Service Manual page 132

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

Message
START STOP LOCKED
START-STOP MODE SELECTED
STATUS OK
TECHNICIAN RESET REQUIRED
(A21)
TEST #1(to #15) XX% COMPLETE
TIME SELECTION NOT CHANGED
TRIP START ENTERED
UNIT BATTERY TOO LOW
UNIT SHUTDOWN - DOOR OPEN
UNIT SHUTDOWN - SEE ALARM LIST
UNIT SHUTDOWN - RMS1(2)
UNKNOWN CARD - REMOVE CARD
WARNING: DIESEL RESTART ON
WARNING: NO TEMP CONTROL
WRONG UNIT TYPE, REMOVE CARD
62-11389
MessageCenter MESSAGES - Continued
The set point has been locked into Start-Stop Operation. Continu-
ous Run can not be selected.
Start-Stop Operation has been selected.
The unit is operating correctly.
AL11 (Low Engine Oil Pressure) or AL12 (High Coolant Temperat-
ure) has been activated three times in the last two hours and the
unit has been locked out. The unit must be brought to a Carrier
Transicold Dealer for service.
Pretrip is currently running this test and is XX% complete.
A time change was started but not entered (saved) in Configuration
List.
The Trip Start marker has been placed in the DataLink data record-
er.
The unit battery has dropped below 7 volts for more than 10 sec-
onds.
The unit has shutdown because the refrigerated compartment door
is open.
An active shutdown alarm has shut the unit down.
The unit has shutdown because switch is open. May be connected
to a door or a remote control switch.
A defective or different type of PC Card has been inserted into the
PC Card slot. The microprocessor can not recognize any data on
the card. The card may be safely removed from the micropro-
cessor.
When electric power is not available while the unit is operating in
Standby Operation, the unit will switch to Engine Operation.
The temperature sensors have failed and the unit has entered
Cargo Protect Mode. Refer to Section 4.8.1.
A configuration PC card has been inserted into the PC Card slot.
The unit model family type on the PC card is not in the same unit
family type as the microprocessor. The card may be safely re-
moved from the microprocessor.