Carrier VECTOR 6500 Operation & Service Manual page 119

Single-temp trailer and rail refrigeration units with advancet microprocessor
Table of Contents

Advertisement

S PM 1 - 5 RESET INTERVAL
Note:
This Configuration will not display
for those meters that are con-
figured OFF.
PRODUCTSHIELD SETUP
NOTE: Refer to Section 4.7.3 for
more information on the following
settings.
S PRODUCTSHIELD ECONO
Table 5−2 Microprocessor Configurations - Continued
OFF
ENGINE
PROTECT
HOURS
0 or 50 TO 30,000
hours in 50 hour in-
crements
SWITCH ON
PROTECT
HOURS
0 or 50 TO 30,000
hours in 50 hour in-
crements
STANDBY HOURS
0 or 50 TO 30,000
hours in 50 hour in-
crements incre-
ments
START CYCLES 0
or 1,000 TO
90,000 CYCLES in
1,000 cycle incre-
ments
HIGH SPEED
HOURS
0 or 50 TO 30,000
hours in 50 hour in-
crements
COMPRESSOR
RUN HOURS
0 OR 50 to 30,000
hours in 50 hour in-
crements
MAINTENANCE
DAYS
0 OR 10 to 990
days in 10 day in-
crements
OFF
GO TO
START/STOP
GO TO
CONTINUOUS
The value to be entered here is the desired number
of hours, cycles or days between PM Maintenance
Alarms for this meter.
When the meter is reset, the value selected here
will be added to the to the present meter reading to
indicate to the microprocessor when the next ser-
vice interval alarm is to be activated.
When a PM hour meter is configured as a Mainten-
ance Days meter, that meter will not count a specif-
ic instance such as hours of operation or number of
cycles for a particular component. The meter is
connected to the real time clock and will activate
the alarm after the entered number of days has
elapsed.
Press "=" to access the ProductShield menu. The
information set in the following configurations can
be read in the Unit Data list.
OFF = ProductShield Econo is OFF
GO TO START/STOP = Allows unit to be set for
and operate in Continuous Run until ambient tem-
perature falls within a user-defined range when
unit will go to START/STOP. This allows energy
savings while offering Continuous Run operation
protection when ambient is outside range. Unit will
return to Continuous Run when ambient goes be-
yond range.
GO TO CONTINUOUS = Allows unit to be set for
and operate in START/STOP until ambient temper-
ature falls outside a user-defined range when unit
will go to Continuous Run. This provides continuous
air flow and good product protection for extreme
ambient temperatures. Unit will return to START/
STOP when ambient comes back inside range.
5−17
62-11389