14.Remove the mica shim that is between the stator and
the rotor.
15.Install the fan onto the rotor.
NOTE
The fan must be installed with blades away from
the engine.
16.Torque the fan screw to 10-12 foot-pounds (14 to 16
Nm.
17.Feed all the wires through the inside of the fan cover
side opening. Ensure there are no loops or wires lay-
ing on the stator end.
18.Install the fan cover (Item 3) onto the generator sta-
tor and install the remaining mounting screws and
washers.
NOTE
Make sure the insulation on lead wires is not
damaged during assembling of the fan cover.
Each mounting screw must be assembled with
two washers.
19.Torque the stator mounting screws to 33-37 foot
pounds (44.8Nm to 50.1 Nm).
Mark each stator screw after it is torqued to
ensure that all the screws are torqued.
20.Assemble the strain grommet (Item 12).
21.Reconnect wires.
22.Reassemble engine into unit.

8.9.10 Sensor Checkout

An accurate ohmmeter must be used to check
resistance values shown in Table 8−5 or Table 8−6.
Due to variations and inaccuracies in ohmmeters,
thermometers or other test equipment, a reading within
2% of the chart value would indicate a good sensor. If a
sensor is bad, the resistance reading will usually be
much higher or lower than the resistance values given in
the tables.
Two preferred methods of determining the actual test
temperature at the sensor, is an ice bath at 32_F (0_C)
or a calibrated temperature tester.