TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK)
0026 00
UNIT MAINTENANCE PROCEDURES
Lighting Fixtures
Permanently Mounted Fixture Ballast Replacement: Turn off lighting system circuit breaker
#19 on the Power Distribution Panel. Referring to Figure 5, remove the connectors at the
fixture, tag the wires connected to the ballast and disconnect the wires. Remove the four
machine screws from the ballast plate and remove the ballast.
Install the replacement ballast, connect wires and wire nuts. Attach access plate and tighten
machine screw. Reconnect power line connectors.
BALLAST
Figure 5. Lamp Assembly.
Removable Fixture Ballast Replacement: Remove the machine screw from the access plate
and remove the plate. Label and disconnect the ballast wires. Remove the four machine
screws from the ballast plate and remove the ballast.
Install the replacement ballast and connect wires and wire nuts. Attach the access plate and
tighten the machine screw.
Power cord: Remove the machine screw from the access plate and remove the plate. Label
and disconnect the power cord wires. Install a replacement power cord, connect wires and wire
nuts. Attach access plate and tighten machine screw.
Emergency Light Battery/Charger: Turn off lighting system circuit breaker #19 on the Power
Distribution Panel. Remove the access panel and the connector at the test switch and lamp.
Label and disconnect the wires connected to the battery/charger. Remove the hardware and
battery/charger from the fixture.
Install the replacement battery/charger, lamp and test switch. Connect wires, wire nuts and
connector to the test switch and lamp. Attach access plate and tighten machine screw.
END OF WORK PACKAGE