Icom IC-M71 Instruction Manual page 102

Vhf marine transceiver
Hide thumbs Also See for IC-M71:
Table of Contents

Advertisement

CONTAINERIZED KITCHEN (CK)
TROUBLESHOOTING PROCEDURES (ELECTRICAL SYSTEM)
Table 1. Troubleshooting Procedures (Electrical System) - Continued
Malfunction
Interior lights do not
work
No power at one or
more receptacles
END OF WORK PACKAGE
TM 10-7360-226-13&P
Test or Inspection
Check generator fuel level
Check for dirty fuel filter/water
separator
Check air cleaner restriction
indicator for indication of a clogged
air cleaner (inside access door by
cook center)
Ambient temperature below 40
No other electrical components
operate
All other electrical components
operate
No other electrical components
operate
All other electrical components
operate properly
0010 00-3/4 Blank
Corrective Action
Refill fuel tank
Service fuel filter/water
separator (Refer to TM 9-6115-
642-10)
Service air cleaner assembly
(Refer to TM 9-6115-642-10)
o
F
Turn master switch (generator
control panel) to PREHEAT for
no more than 30 seconds
before cranking engine. Refer
to TM 9-6115-642-10
Notify unit maintenance
See "No Power to Kitchen"
Check/reset lighting circuit
breaker (#19 on Power
Distribution Panel)
Notify unit maintenance
See "No Power to Kitchen"
Check/reset ground fault
interrupter (on receptacle next
to spice rack)
Notify unit maintenance
0010 00